Hard Wire Kit
Part No: AYAGALA01
Description
Hard Wire Junction Box (Direct Wire
The junction box provides a protected enclosure for electrical connections as required by some electrical codes.
The hard wire junction box is intended to be mounted on the floor or the adjacent wall.
The junction box is furnished with approximately
An optional 230/208V or 265V power switch assembly is available for use with the hard wire junction box or subbase. The switch provides a POWER ON/OFF function at the unit as required by some electrical codes.
A replacement junction box cover plate is provided with each switch kit.
For additional information, refer to the Power Switch Installation Instructions.
Receiving
Upon receipt of the product, inspect the shipping carton for signs of visible damage. Report any damage or shortage to the carrier and note it on the delivery receipt. Unit must be stored in its original shipping carton in a dry, secure place prior to its installation and use.
Installation
The installation and servicing of this equipment should performed by qualified, experienced technicians.
Junction Box Kit Installation and Wiring Procedure
EIectrical connections at the unit must be made after the unit chassis is installed in the wall sleeve. The installer must determine and supply the mounting components for attaching the junction box to the wall or door.
WARNING
Hazardous Voltage!
Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power can not be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury.
Important Note:
The unit OFF switch does not disconnect all electrical power to this unit.
CAUTION
Use Copper Conductors Only!
Unit terminals are not designed to accept other types of conductors. Failure to use copper conductors may result in equipment damage.
Important Note:
All wiring must comply with applicable
local and national codes. Types and location of disconnect switches must comply with all applicable codes.
1.Remove the cover plate from the junction box
2.Mount the junction box to the wall or floor within 28 inches (711
mm)of the lower right corner of the wall sleeve.
3.If a disconnect switch is to be used, make electrical connections to it and mount the switch in the junction box. Refer to the Power Switch Installation Instructions.
4.Remove control panel assembly by removing the two screws holding control panel in place. Rotate the panel forward.
5.Disconnect the power cord leads from all electrical connections including the ground wire.
6.Remove the power cord clamp and the power cord from the unit.
7.For
8.Remove the retaining ring from the threaded portion of the straight conduit clamp. Insert the three wires into the metal box through one of the two openings in the box. Replace the hole cover grommet into the unused hole to prevent objects from entering the box.
9.Replace the retaining ring back on the conduit clamp inside the metal box and tighten the ring securely.
10.Insert the three wires extending from the metal box into the incoming power opening on the unit so that approximately 20 inches (508 mm) of the wires protrude through the opening.
11.Attach the metal box to the chassis with the two screws provided. See Figure 50.
12.Insert the wire tie into the
Copyright ©2008 LG Electronics. Inc. All right reserved. | - 33 - |
Only for training and service purposes | LGE Internal Use Only |
|