COMPLAINT | CAUSE | REMEDY |
|
|
|
Compressor cycles | Voltage | Check the voltage. See the limits on the preced- |
on overload. |
| ing page. If not within limits, call an electrician. |
|
|
|
| Overload | Check overload, if externally mounted. |
|
| Replace if open. (If the compressor temperature |
|
| is high, remove the overload, cool, and retest.) |
|
|
|
| Fan motor | If not running, determine the cause. Replace if |
|
| required. |
|
|
|
| Condenser air flow | Remove the cabinet. inspect the interior surface |
| restriction | of the condenser; if restricted, clean carefully |
|
| with a vacuum cleaner (do not damage fins) or |
|
| brush. Clean the interior base before |
|
| reassembling. |
|
|
|
| Condenser fins | If condenser fins are closed over a large area |
| (damaged) | on the coil surface, head pressures will increase, |
|
| causing the compressor to cycle. Straighten the |
|
| fins or replace the coil. |
| Capacitor | Test capacitor. |
|
|
|
| Wiring | Check the terminals. If loose, repair or replace. |
| Refrigerating system | Check the system for restriction. |
Insufficient cooling or | Air filter | If restricted, clean of replace. |
heating | Exhaust damper door | Close if open. |
|
|
|
| Unit undersized | Determine if the unit is properly sized for the area to |
|
| be cooled. |
Excessive noise. | Cross flow fan | Check the set screw or clamp. If loose or missing, |
|
| correct. If the blower or fan is hitting air guide, |
|
| rearrange the air handling parts. |
| Copper tubing | Carefully rearrange tubing not to contact, |
|
| compressor, shroud, and barrier. |
|
|
|
Copyright ©2008 LG Electronics. Inc. All right reserved. | - 43 - |
Only for training and service purposes | LGE Internal Use Only |
|