208/230 Volt Units
1.Remove and discard the white lead from the wire assembly.
2.Connect the black lead to the line 2 terminal on the control board.
3.Connect the red lead to the common (C) terminal on the capacitor.
4.Connect the ground wire to the partition panel where the ground wire on the power cord was located.
Use the supplied green ground screw.
5.Connect the red lead in the wire assembly at the junction box to the red lead of the field power source.
6.Connect the black lead in the wire assembly at the junction box to the black lead of the field power source.
7.Connect the ground wire of the field power source to the ground wire of the wire assembly at the junction box.
8.Install the junction box cover plate.
9.Reinstall the control panel assembly.
265 Volt Units
1.Remove and discard the red lead from the wire assembly .
2.Connect the black lead to the center terminal of the fuse holder.
3.Connect the white lead to the common (C) terminal on the capacitor.
4.Connect the ground wire to the partition panel where the ground wire on the power cord was located.
Use the supplied green ground screw.
5.Connect the white lead of the wire assembly at the junction box to the white lead of the field power source.
6.Connect the black lead of the wire assembly at the junction box to the black lead of the field power source.
7.Connect the ground wire of the field power supply to the bare ground wire of the wire assembly at the junction box.
8.Install the junction box cover plate.
9.Reinstall the control panel assembly.
Figure 50 - Mounting Hard Wire Junction Box Kit
| Wall Sleeve |
|
|
| Ground Wie |
|
| with Eyelet |
|
| Terminal |
Cover plate | 28 Inch es Max | Power Leads |
| ||
| with Push on | |
|
| |
| Conduit | Connectors |
| Metal Box | |
|
| |
|
| with Straight Clamp |
Figure 51 - Metal Box Location
Control Panel
Base Pan
Bracket
Figure 52 - Electrical Wiring Routing
Right Side of Chassis
Wire Tie
3/16 Inch
Diamenter Hole
Electrical Supply Wires
Back of Control Panel
Copyright ©2008 LG Electronics. Inc. All right reserved. | - 34 - |
Only for training and service purposes | LGE Internal Use Only |
|