Manuals
/
LG Electronics
/
Household Appliance
/
Air Conditioner
LG Electronics
LP121CEM-Y8 manual P/NO MFL42137114, February
Models:
LP121CEM-Y8
1
48
48
Download
48 pages
50.4 Kb
41
42
43
44
45
46
47
48
<
>
Troubleshooting
Specification
Install
Wiring Diagram
Hard Wire Kit
LED Diagnostics
Disassembly Instructions
Checklist
Quick Heater Recovery
Safety
Page 48
Image 48
P/NO : MFL42137114
FEBRUARY, 2008
Page 47
Page 48
Image 48
Page 47
Contents
Window Air Conditioner
SVC MANUAL
MODEL LP121CEM-Y8
Internal Use Only
1. Specification
LGE Internal Use Only
Model
LP121CEM-Y8
1.2 FEATURES AND BENEFITS
THE SLEEVE AND THE REAR GRILLE
Fan-Only Setting - High/Low
LED Diagnostics
Door Switch/Occupancy Sensor
Outdoor Air Temperature Switchover
Quick Heater Recovery
Indoor Filters
1.3 CONTROL LOCATIONS
OPERATION ELECTRIC HEATING MODEL
VENTILATION
COOLING ONLY MODEL
1.4 ADDITIONAL CONTROLS
REMOVING THE FRONT GRILLE
ADDITIONAL CONTROLS
TEMPERATURE LIMITING
REMOTE/LOCAL CONTROL
ENERGY SAVER
FRONT DESK CONTROL
REMOTE WALL THERMOSTAT
2. Disassembly Instructions
2.1 MECHANICAL PARTS
2.1.1 FRONT GRILLE
2.1.2 CONTROL BOX
2.2 AIR HANDLING PARTS
2.2.1 ELECTRIC HEATER ELECTRIC HEATER MODEL ONLY
2.2.2 CROSS FLOW FAN
2.2.3 AXIAL FAN
2.3. ELECTRICAL PARTS
2.2.4 SHROUD
2.3.1 OUTDOOR MOTOR
2.3.3 COMPRESSOR
2.3.5 POWER CORD
2.3.6 P.C.B
2.4 REFRIGERATION CYCLE
2.4.1 CONDENSER
2.4.2 EVAPORATOR
2.4.3 CAPILLARY TUBE
Replacement of the refrigeration cycle
Figure 21 A-Pulling Vacuum
Figure 21 B-Charging
3. Installation
3.1 HOW TO INSTALL THE UNIT
Dimension of air conditioner
Dimension of sleeve assembly optional
3.2 WALL SLEEVE INSTALLATION
3.2.1 Wall Case Installation Data
General
Installation of Wall Case in Wall Opening
3.2.2 PREPARATION OF THE FRONT GRILLE
Preparation of the Wall Case for All Types of Construction
Brick, Frame, Stucco and Shingle Construction
Only for training and service purposes
LGE Internal Use Only
FRAME AND BRICK VENEER INSTALLATION
Sub-Base Connected
WALL SECTION - DETAILED SIDE VIEW
Cord Set Connected
3.2.3 UNIT INSTALLATION
3.3.2 ELECTRICAL SAFETY
3.3 ELECTRICAL REQUIREMENTS
3.3.1 ELECTRICAL DATA FOR 230/208V MODEL
230/208 volt receptacle configuration
4. FieldInstalledAccessories
Installation
Control Panel Key Lock
Description
Condensate Disposal Pump Kit Installation
Installation
Description
Receiving
10. Place the top cover assembly back into the unit
LGE Internal Use Only
15. Assembly the unit back following the reverse order of disassembly
Installation
on any PTAC installation
Architecture Grille Aluminum - Single
Pack
Drain Installation
Condensate Drain kit
Installation
Receiving
Outdoor Drain Kit Installation
Figure 42 - Outdoor Drain Kit Installation
Indoor Drain Kit Installation
Leveling Legs
Installation
Checklist
Leveling Leg Assembly
Figure 48 - Leveling Leg Assembly
Installation on Wall Sleeve
Figure 49 - Leveling Leg Installation on Wall Sleeve
Hard Wire Kit
Junction Box Kit Installation and Wiring Procedure
Installation
Description
208/230 Volt Units
265 Volt Units
Figure 50 - Mounting Hard Wire Junction Box Kit
Figure 52 - Electrical Wiring Routing
Remote Escutcheon Kit
Installation
Description
Receiving
Subbase
Installation
Description
Receiving
Figure 59 - Dimensions
Figure 60 - Wiring Diagram
The proper subbase must be ordered to obtain the correct
electrical receptacle. Figure
5. TroubleshootingGuide
5.1 OUTSIDE DIMENSIONS
5.2 PIPING SYSTEM
5.3 TROUBLESHOOTING GUIDE
Unit is running but cooling is ineffective Ineffective Cooling
Fails to Start
COMPLAINT
CAUSE
REMEDY
ROOM AIR CONDITIONER VOLTAGE LIMITS
COMPLAINT
CAUSE
REMEDY
COMPLAINT
CAUSE
REMEDY
6. PipingDiagrams
Th2 Th1 HEAT EXCHANGER EVAPORATOR
CAPILLARY TUBE HEAT EXCHANGER CONDENSER COMPRESSOR
7.Schematic Diagram
In part A, there are 3 types
In part B, there are 3 types
8. ExplodedView
CONDENSER OUTDOOR SERVICE REPLACEMENT PROCEDURE
Copper pipe Aluminum pipe
Brazing point in
assembling or
P/NO MFL42137114
FEBRUARY