18.Off Timer On/Off (Command : f c)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232C

 

Controlling the Multiple Product

 

 

 

 

 

 

 

19.On Timer Time(Command : f d) Transmission / Receiving Protocol

18.Off Timer On/Off (Command : f c)

► Set days for Off Timer.

Transmission

Acknowledgement

[f][c][][Set ID][][Data1][Data2][Cr]

[Data1]

0 (Write), FFH(Read)

[Data2]

00 H to FFH

bit0 : Monday Off Timer On(1), Off(0)

bit1 : Tuesday Off Timer On(1), Off(0)

bit2 : Wednesday Off Timer On(1), Off(0)

bit3 : Thursday Off Timer On(1), Off(0)

bit4 : Friday Off Timer On(1), Off(0)

bit5 : Saturday Off Timer On(1), Off(0) bit6 :Sunday Off Timer On(1), Off(0) bit7 : Everyday Off Timer On(1), Off(0)

19.On Timer Time(Command : f d)

► Set On Timer.

Transmission

[c][][Set ID][][OK/NG][Data1][Data2][x]

Acknowledgement

[f][d][][Set ID][][Data1][Data2][Data3][Cr]

[Data1]

0 : Monday

1 : Tuesday

2 : Wednesday

3 : Thursday

4 : Friday

5 : Saturday

6 : Sunday

7 : Everyday [Data2]

00 H to 17 H : 00 to 23 Hours [Data3]

00 H to 3 BH : 00 to 59 Minutes

[b][][Set ID][][OK/NG][Data1][Data2][Data3][x]

*When reading data, FFH is inputted for [Data1], [Data2] and [Data3].

In other cases, all are treated as NG.