34 Plasma Monitor
External Control Device Setup

13. Remote Control Lock Mode (Command2:m)

GTo lock the remote control and front panel controls on the
monitor
Transmission
[k][m][ ][Set ID][ ][Data][Cr]
Acknowledgement
Data 0: lock off 1: lock on
If youre not using the remote control and front panel con-
trols on the monitor, use this mode. When main power is
on/off, remote control lock is released.
[m][ ][Set ID][ ][OK][Data][x]
GTo adjust the screen sharpness.
You can also adjust sharpness in the Picture menu.
Transmission

11. Sharpness (Command2:k)

Data Min: 0 ~ Max: 64
Refer to Real data mapping 1.
[k][k][ ][Set ID][ ][Data][Cr]
Acknowledgement
[k][ ][Set ID][ ][OK][Data][x]

12. OSD Select (Command2:l)

GTo select OSD (On Screen Display) on/off.
Transmission
[k][l][ ][Set ID][ ][Data][Cr]
Acknowledgement
Data 0: OSD off 1: OSD on
[l][ ][Set ID][ ][OK][Data][x]

09. Color (Command2:i)

GTo adjust the screen color.
You can also adjust color in the Picture menu.
Transmission
Data Min : 0 ~ Max : 64
Refer to Real data mapping 1.
[k][i][ ][Set ID][ ][Data][Cr]
Acknowledgement
[i][ ][Set ID][ ][OK][Data][x]

10. Tint (Command2:j)

GTo adjust the screen tint.
You can also adjust tint in the Picture menu.
Transmission
Data Red : 0 ~ Green : 64
Refer to Real data mapping 1.
[k][j][ ][Set ID][ ][Data][Cr]
Acknowledgement
[j][ ][Set ID][ ][OK][Data][x]

08. Brightness (Command2:h)

GTo adjust screen brightness.
You can also adjust brightness in the Picture menu.
Transmission
Data Min : 0 ~ Max : 64
Refer to Real data mapping 1.
[k][h][ ][Set ID][ ][Data][Cr]
Acknowledgement
[h][ ][Set ID][ ][OK][Data][x]
Data Min : 0 ~ Max : 64
Data Min : 0 ~ Max : 64
Data Red : 0 ~ Green : 64
Data Min : 0 ~ Max : 64
Data 0: OSD off 1: OSD on
Data 0: lock off 1: lock on

07. Contrast (Command 2:g)

GTo adjust screen contrast.
You can also adjust contrast in the picture menu.
Transmission
Data Min : 0 ~ Max : 64
Refer to Real data mapping1as shown below.
[k][g][ ][Set ID][ ][Data][Cr]
Acknowledgement
[g][ ][Set ID][ ][OK][Data][x]
* Real data mapping 1
0 : Step 0
A : Step 10 (SET ID 10)
F : Step 15 (SETID 15)
10 : Step 16 (SET ID 16)
63 : Step 99 (SET ID 99)
64 : Step 100
Data Min : 0 ~ Max : 64