SPCI Command Tree
M370046-01 A-21
A
Get Output
Calibration
Parameters
[:]CALibration[<channel>]:PARameter
[:OUTPut]
Queries and loads the output
calibration parameters in
arbitrary program block data
format.
?|<arbitrary
program block
data>
Yes
Get Analog
Programming
Calibration
Parameters
[:]CALibration[<channel>]:PARameter
:APRogram
Queries and loads the APG
calibration parameters in
arbitrary program block data
format.
?|<arbitrary
program block
data>
Yes
Table A-5 SCPI Commands to Clear All Protection Mechanisms
Function SCPI Command Description
Parameter and
Range Query
Clear Output
Protection
[:]OUTPut[<channel>]:PROTection:CLEar Clears the currently set
alarms.
N/A
Table A-6 SCPI Commands for Foldback Protection
Function SCPI Command Description
Parameter and
Range Query
Set Output
Foldback
Delay
[:]OUTPut[<channel>]:PROTection
:FOLDback:DELay
Set the delay time (seconds)
before foldback protection
is triggered.
?|<Delay - (0.5-50)> Yes
Set Output
Foldback
Mode
[:]OUTPut[<channel>]:PROTection
:FOLDback[:MODE]
Select condition for
foldback.
?|CV|CC|NONE Yes
Table A-4