A-32 M370046-01
SCPI Command Reference
Set
Questionable
Status
Temperature
Negative
Transition
Register
[:]STATus[<channel>]:QUEStionable
:TEMPerature:NTRansition
Access the Questionable
Temp Negative Trans Filter
Register.
See Table 5-15 on page 5–
45.
?|<Transition Flags
- (0–65535)>
Yes
Set
Questionable
Status
Temperature
Positive
Transition
Register
[:]STATus[<channel>]:QUEStionable
:TEMPerature:PTRansition
Access the Questionable
Temp Positive Trans Filter
Register.
See Table 5-15 on page 5–
45.
?|<Transition Flags
- (0–65535)>
Yes
Query
Questionable
Status Voltage
Condition
Register
[:]STATus[<channel>]:QUEStionable
:VOLTage:CONDition?
See Table 5-15 on page 5–
45.
Query the
Questionable
Voltage Condition
Register
Yes
Set
Questionable
Status Voltage
Enable
Register
[:]STATus[<channel>]:QUEStionable
:VOLTage:ENABle
Access the Questionable
Volt Enable Register.
See Table 5-15 on page 5–
45.
?|<Enable Flags -
(0–65535)>
Yes
Query
Questionable
Status Voltage
Event
Register
[:]STATus[<channel>]:QUEStionable
:VOLTage[:EVENt]?
Query the Questionable Volt
Event Register.
See Table 5-15 on page 5–
45.
Yes
Table A-10