Alarms and Errors

 

 

Clearing Alarms

 

 

Clearing Triggered and Manual Alarms

 

 

 

To clear a triggered alarm, use one of the following methods:

 

 

 

• Turn the power supply Off and then On.

 

 

 

• Press and hold the rotary Adjust/Enter control for 3 seconds.

 

 

 

• Press the reset key combination (Flash Fail ONLY). See “Resetting the

 

 

 

Power Supply” on page 3–39.

 

 

 

To clear a manual alarm:

 

 

 

1. Press and hold the rotary Adjust/Enter control for 3 seconds.

 

 

 

 

 

The ALr CLr message will be displayed on the front panel for a few

 

3

 

seconds.

 

 

 

 

 

 

 

 

 

 

Important: When an alarm is cleared by using this method, only the current

 

 

 

highest precedence alarm is cleared. If another alarm has occurred, then this

 

 

 

alarm will now become the highest precedence alarm and will begin blinking on

 

 

 

the display.

 

 

 

 

2. Repeat the alarm clearing until you have cleared all alarms.

 

 

Clearing a Flash Failure Alarm

 

 

 

The Flash Failure alarm is the only exception for clearing alarms. Flash

 

 

 

failure can only be cleared by a reset (see “Resetting the Power Supply”

 

 

 

on page 3–39) or by power cycling the unit.

 

 

 

To clear a triggered alarm, use one of the following methods:

 

 

 

• Turn the power supply Off and then On.

 

 

 

• Press and hold the rotary Adjust/Enter control for 3 seconds.

 

 

 

• Press the reset key combination (Flash Fail ONLY). See “Resetting

 

 

 

the Power Supply” on page 3–39.

 

 

 

The SCPI command (s) for these instructions are:

 

 

 

[:]OUTPut[<channel>]:PROTection:CLEar

 

 

M370046-01

3-19