| Alarms and Errors |
|
| |
Clearing Alarms |
|
| ||
Clearing Triggered and Manual Alarms |
|
| ||
| To clear a triggered alarm, use one of the following methods: |
|
| |
| • Turn the power supply Off and then On. |
|
| |
| • Press and hold the rotary Adjust/Enter control for 3 seconds. |
|
| |
| • Press the reset key combination (Flash Fail ONLY). See “Resetting the |
|
| |
| Power Supply” on page |
|
| |
| To clear a manual alarm: |
|
| |
| 1. Press and hold the rotary Adjust/Enter control for 3 seconds. |
|
| |
|
| |||
| The ALr CLr message will be displayed on the front panel for a few |
| 3 | |
| seconds. |
| ||
|
|
| ||
|
|
|
|
|
| Important: When an alarm is cleared by using this method, only the current |
|
| |
| highest precedence alarm is cleared. If another alarm has occurred, then this |
|
| |
| alarm will now become the highest precedence alarm and will begin blinking on |
|
| |
| the display. |
|
|
|
| 2. Repeat the alarm clearing until you have cleared all alarms. |
|
| |
Clearing a Flash Failure Alarm |
|
| ||
| The Flash Failure alarm is the only exception for clearing alarms. Flash |
|
| |
| failure can only be cleared by a reset (see “Resetting the Power Supply” |
|
| |
| on page |
|
| |
| To clear a triggered alarm, use one of the following methods: |
|
| |
| • Turn the power supply Off and then On. |
|
| |
| • Press and hold the rotary Adjust/Enter control for 3 seconds. |
|
| |
| • Press the reset key combination (Flash Fail ONLY). See “Resetting |
|
| |
| the Power Supply” on page |
|
| |
| The SCPI command (s) for these instructions are: |
|
| |
| [:]OUTPut[<channel>]:PROTection:CLEar |
|
|