A-24 M370046-01
SCPI Command Reference
Query the
Error Queue
for the
number of
entries.
[:]SYSTem[<channel>]:ERRor:COUNt? Returns the number of
errors currently in the error
queue.
Yes
Select Voltage
Analog
Programming
Input Voltage
Input Level/
Range
[:]SYSTem[<channel>]:COMMunicate
:APRogram:LEVel[:VOLTage][:ISOLated]
Select level for Voltage
APG. Level can be between
2 -10 volts.
?|<Level (2–
10)>|MAXimum|MI
Nimum
Yes
Select Current
Analog
Programming
Input Voltage
Input Level/
Range
[:]SYSTem[<channel>]:COMMunicate
:APRogram:LEVel:CURRent[:ISOLated]
Select level for Current
APG. Level can be between
2 -10 volts.
?|<Level(2–
10)>|MAXimum|MI
Nimum
Yes
Select the
address to
communicate
with.
[:]SYSTem[<channel>]:COMMunicate
[:MCHannel]:ADDRess
Select the current device to
receive the commands. The
parameter for this
command is the address set
on the front panel under the
remote
Yes
Select
Address
[:]SYSTem:COMMunicate[:SELF]:ADDRess Select the power supply
unit to communicate with.
?|<Address (1–30) Yes
Setup the
Voltage
control APG
source
[:]SYSTem[<channel>]:REMote:SOURce
[:VOLTage]
Alter or query the state of
the remote programming
voltage APG source.
?|LOCal|AVOLtag
e|IAVoltage|ARE
Sistive|IAResis
tive
Yes
Table A-9
System Commands (Continued)