Local Operation
Table 3-9 Power Supply Default Settings
Parameter | Setting |
|
|
UVP | 0 V |
Foldback trigger | None |
Foldback delay | 0.5 s |
Current Share Mode | MASTer |
Alarm Output Latches | 263 (0 × 107, all latches enabled) |
Alarms Mask | 2047 (0 × 7FF, all enabled) |
Interlock | Disabled |
Voltage Analog Programming | Off |
Voltage APG Scale | 10 V |
Current Analog Programming | Off |
Current APG Scale | 10 V |
|
|
Hard Reset | The hard reset performs the same functions as a soft reset, but will also | |
| clear all calibration constants. Do not perform a hard reset unless you are | |
| planning to | |
| To reset the power supply: | |
| 1. | Turn the front panel power switch to the Off position. |
| 2. | Allow the unit to power down. |
| 3. | When the fans are off and the front panel displays are not illuminated, |
|
| turn the power switch to the On position. |
| 4. | Press and hold the OUTPUT ENABLE Main and OUTPUT |
|
| ENABLE Aux buttons. |
|
| The front panel should display P5U S rS. |
| 5. | When the display reads P5u Clr, release the OUTPUT ENABLE |
|
| Main and OUTPUT ENABLE Aux buttons. After 1 second the model |
|
| number will appear on the display for 1 second. |
The power supply has been reset.