OPERation Status Register

OPERation Status Register

The operation status register is a standard SCPI, 16-bit register which contains information about conditions which are part of the power supply's normal operation. The Operation Status data structure has the operation status register and two sub-registers to represent shutdown and protection shutdown. Each of the sub-registers is summarized in a summary bit.

Figure 5-20 represents the Operation Status data structure. The “+” represents the logical summation/or of bits in a register. Table 5-11, Table 5-12, and Table 5-13 describe the meanings of each bit as well as the bit number and bit weight.

STATus:O PERation:SHUTdown:PRO Tection

Over VOLTage

0

 

Under VOLTage

1

 

Over CURR ent

2

 

Not Used

3

 

AC Off

4

 

Over TEM Perature

5

 

N ot Used

6

+

Foldback

7

Fan Failure

8

 

Not Used

9

 

Not U sed

10

 

Not U sed

11

 

Not U sed

12

 

Not Used

13

 

Not Used

14

Never Used

Not Used

15

STATus:O PERation:SHU Tdown

PROTection Sum m ary

0

 

IN Terlock

1

 

Not Used

2

 

External Shutdown

3

 

Not Used

4

 

Not Used

5

 

Not Used

6

+

Not Used

7

Not Used

8

 

Not Used

9

 

Not Used

10

 

Not Used

11

 

Not Used

12

 

Not Used

13

 

Not Used

14

Never Used

Not Used

15

STATus:OPERation:CSHare

M ASTer

0

 

SLAve

1

 

Not U sed

2

 

Not U sed

3

 

N ot Used

4

 

Not Used

5

 

Not U sed

6

+

Not U sed

7

Not U sed

8

 

Not U sed

9

 

Not Used

10

 

Not Used

11

 

Not Used

12

 

Not Used

13

 

Not Used

14

Never Used

Not Used

15

STATus:OPER ation

 

5

CALibrating

0

 

 

 

Not U sed

1

 

 

 

Not U sed

2

 

 

 

Not U sed

3

 

 

 

M EASuring

4

 

 

 

W aiting for TRIGger

5

 

 

 

Not U sed

6

 

+

To Status

Not U sed

7

 

 

Byte Bit 7

Not U sed

8

 

 

 

 

 

SHU Tdow n Sum m ary

9

 

 

 

Local Lock

10

 

 

 

Current Share Sum m ary

11

 

 

 

Constant C urrent M ode

12

 

 

 

Constant Voltage M ode

13

 

 

 

PROG ram Running

14

Never Used

 

Not Used

15

 

Figure 5-20Operation Status Register Fanout

M370046-01

5-35

Page 161
Image 161
Xantrex Technology XTR 850 WATT SERIES manual OPERation Status Register, 20Operation Status Register Fanout