User Setting Memory Locations
User Setting Memory Locations
There are three user setting memory locations available for storing frequently used configurations. These user setting memory locations help to facilitate multiple users of an XTR power supply who have different setups or when multiple loads are used that have different requirements. Table
Table 3-8 User Accessible Saved/Recalled Settings
Voltage Setpoint
Current Setpoint
Over Voltage Protection (OVP)
Over Temperature Protection (OTP)
Autostart OUTPUT ENABLE Main3
Autostart OUTPUT ENABLE Aux
Foldback Mode
Foldback Delay
Shutdown Logic
Voltage Analog Programming (VAP) Mode
Voltage Analog Programming (VAP) Level
Current Analog Programming (CAP) Mode
Current Analog Programming (CAP) Level
Alarm Latches
Front Panel Timeout
Saving User Setting Memory Locations
To save user setting memory locations:
1.Turn the
SAUE is displayed on the output voltage display with a number indicating a preset position which is displayed on the output current display.
2.Turn the rotary Adjust/Enter control to select a preset position from 1 to 3.
3.Press the rotary Adjust/Enter control.
SAuE done is displayed on the output voltage display.