OPERation Status Register
M370046-01 5-37
5
Table 5-12
OPERation SHUTdown Status Register
Bit Bit Weight Bit Name Description
0 1 PROTection Reflects the summary of the PROTection sub-
register.
1 2 INTerlock The power supply is shut down by INTerlock signal.
2 4 Not Used Not Used
3 8 External Shutdown The power supply is shut down by External
Shutdown signal.
Table 5-13
OPERation SHUTdown PROTection Status Register
Bit Bit Weight Bit Name Description
0 1 OVP Over Voltage protection has tripped.
1 2 UVP Under Voltage protection has tripped.
2 4 OCP Over Current protection has tripped.
3 8 Not Used Not Used
416 AC Off AC failure protection has tripped.
532 OTP Over Temperature protection has tripped.
664 Not Used Not Used
7128 Foldback Foldback protection has tripped.
8256 Fan Fan failure protection has tripped.