Terminal Configuration

Multichannel Address Setting

The power supply multichannel address can be set to any address between 1 to 30. All units that are connected together via the RS-232 or RS-485 connector must have a unique multichannel address.

To set the address:

1.Select the appropriate communication port as described “Selecting the Appropriate Communication Port” on page 5–20.

If more than one unit has the same multichannel address when connected through the RS-485 connector, then collisions are possible, resulting in garbled responses to queries.

2.Press the rotary Adjust/Enter control.

ADDR is displayed on the output voltage display.

3.Turn the rotary Adjust/Enter control to select the desired multichannel address between 1 to 30.

4.Press the rotary Adjust/Enter control to commit the new address.