Local Operation

Connecting to the Load in Remote Sensing Mode

Connect the negative (–) output terminal of one power supply to the positive (+) output terminal of the next power supply. The more positive supply’s positive sense line should connect to the positive terminal of the load (or distribution point). Its return sense line should connect to the connection between the two units at the same spot as the negative supply’s positive sense line. The return sense line of the negative supply should be connected to the return of the load. See Figure 3-7.

CAUTION: Equipment damage

Do not connect sense lines through relays.

Figure 3-7Load Connections in Remote Sensing Mode

3-44

M370046-01

Page 88
Image 88
Xantrex Technology XTR 850 WATT SERIES manual Connecting to the Load in Remote Sensing Mode