M370046-01

A-17

Table A-3SCPI Commands for Output Control

 

 

 

Parameter and

 

Function

SCPI Command

Description

Range

Query

 

 

 

 

 

Set Current

[[:]]SOURce[<channel>]]:COMBine:CSHare[:

Set the XTR to operate in the

?MASTer

Yes

Sharing Mode

MODE]

current share master or slave

SLAVe

 

 

 

mode. If only a single unit is

 

 

 

 

being used it should be set to

 

 

 

 

master.

 

 

 

 

 

 

 

Set Output

[[:]SOURce[<channel>]]:COMBine:CSHare

Sets the output latches for

?<alarm sum of

Yes

latches for the

[:MODE]

the alarms.

latch flags>

 

alarms

 

 

 

 

 

 

 

 

 

Set

[[:]SOURce[<channel>]]:CURRent[:LEVel]

Set current set point

?<Current Set

Yes

(Immediate)

[:IMMediate][:AMPLitude]

(immediate)

Point>MAXimum

 

Current Set

 

 

MINimum

 

point

 

 

 

 

 

 

 

 

 

Set

[[:]SOURce[<channel>]]:VOLTage[:LEVel]

Change voltage set point

?<Voltage Set

Yes

(Immediate)

[:IMMediate][:AMPLitude]

(immediate)

Point>MAXimum

 

Voltage Set

 

 

MINimum

 

point

 

 

 

 

 

 

 

 

 

Set Over

[[:]SOURce[<channel>]]:VOLTage:PROTect

Set the over voltage

?<OVP Set

Yes

Voltage

ion[:OVERvoltage][:LEVel]

protection level.

Point>MAXimum

 

Protection

 

 

MINimum

 

Level

 

 

 

 

 

 

 

 

 

Set Under

[[:]SOURce[<channel>]]:VOLTage:PROTect

Set the under voltage

?<UVP Set

Yes

Voltage

ion:UNDer[:LEVel]

protection level.

Point>MAXimum

 

Protection

 

 

MINimum

 

Level

 

 

 

 

 

 

 

 

 

SPCI Command Tree

A

Page 215
Image 215