Remote Operation
Table 5-11 OPERation Status Register
Bit | Bit Weight | Bit Name | Description |
|
|
|
|
0 | 1 | CALibrating | Indicates that the supply is in CALibration Mode. |
|
|
|
|
1 | 2 | SETTling | Not implemented |
|
|
|
|
2 | 4 | RANGing | Not implemented |
|
|
|
|
3 | 8 | SWEeping | Not implemented |
|
|
|
|
4 | 16 | MEASuring | Not implemented |
|
|
|
|
5 | 32 | Waiting for Arm | Not implemented |
|
|
|
|
6 | 64 | Waiting for Trigger | Not implemented |
|
|
|
|
7 | 128 | CORRecting | Not implemented |
|
|
|
|
8 | 256 | Not Used | Not Used |
|
|
|
|
9 | 512 | SHUTdown Summary | Reflects the summary of the SHUTdown Sub- |
|
|
| Register. |
|
|
|
|
10 | 1024 | Local Lockout | Front panel lockout |
|
|
|
|
11 | 2048 | Current Share Summary | Reflects the summary of the CSHare |
|
|
|
|
12 | 4096 | Constant Voltage Mode | Reflects the output mode of the supply. |
|
|
|
|
13 | 8192 | Constant Current Mode | Reflects the output mode of the supply. |
|
|
|
|
14 | 16384 | Program Running | Indicates if an Autosequence program is currently |
|
|
| running. |
|
|
|
|
The operation shutdown status register describes the cause of the power supply shutting down the output. More than one bit may be active and multiple actions will be required to restart the unit. The protection shutdown