Analog Programming (APG) and Isolated Analog Programming (ISOL)

Auxiliary Outputs

The auxiliary outputs are an additional isolated source. The auxiliary output has two outputs: +5 V output on J3.9 and a +15 V output on J3.11. The auxiliary output operates independently of the main output. It is enabled or disabled from the front panel by pressing the OUTPUT ENABLE Aux button. When the Aux output is enabled, the OUTPUT ENABLE Aux button is illuminated. Like the main output of the power supply, the Aux also has the ability to Autostart at power up. See “Output Auto Start Mode (Auto Restart)” on page 3–16 and “Auxiliary Auto Start Mode” on page 3–17 for details on controlling this feature.

Table 4-2 provides a summary of the options available for programming output voltage and current set point using an analog source.

Table 4-2Remote Programming Options

Control of…

Programming Scale1

For more info…

Output voltage

2–10 V Voltage source (adjustable)

See page 4–10.

Current set point

2–10 V Voltage source (adjustable)

See page 4–12.

Output voltage

2–10 kΩ Resistive source (adjustable)

See page 4–15.

Current set point

2–10 kΩ Resistive source (adjustable)

See page 4–17.

 

 

 

1.The resolution can be adjusted in increments of 0.1 volts.

4-4

M370046-01

Page 96
Image 96
Xantrex Technology XTR 850 WATT SERIES manual Auxiliary Outputs, 2Remote Programming Options, Control of… Programming Scale