Analog Programming (APG) and Isolated Analog Programming (ISOL)

Table 4-3APG Pins and Functions J1

Pin

Reference

Function

 

 

 

J1.9

VOL_PR

Analog Voltage Programming Input

 

 

 

J1.10

CUR_PR

Analog Current Programming Input

 

 

 

J1.11

VOL_RES_PR

Voltage Resistive Programming Input

 

 

 

J1.12

CUR_RES_PR

Current Resistive Programming Input

 

 

 

J1.13

VOL_MON1

Voltage Monitor. The scale of this output is set by the APG

 

 

voltage input range selected (see Important note below).

J1.14

CUR_MON1

Current Monitor. The scale of this output is set by the APG

 

 

current input range selected (see Important note below).

J1.15

EXT_CC_CV

External CC/CV. Indicates the state of the operate mode. When

 

 

in CV mode, logic high is output and when in CC mode, logic

 

 

low is output. Logic is TTL/CMOS compatible.

 

 

 

J1.16

CSH

Current Share. Used to hook up units for current sharing. Output

 

 

from master unit. Slave units should be left open.

 

 

 

J1.17

REF_I

Current Reference Input. Slave input from current share output

 

 

on the master unit.

 

 

 

J1.18

NC

 

 

 

 

1.Important: Non-isolated monitor lines are only valid in local control, digital remote and non- isolated analog programming modes for the respective voltage and current control. If isolated analog programming is used, the isolated monitor lines should be used as the non-isolated monitoring lines will not accurately reflect the output state of the power supply.

4-6

M370046-01

Page 98
Image 98
Xantrex Technology XTR 850 WATT SERIES manual 3APG Pins and Functions J1, Pin Reference Function