Lincoln Electric 215 Contact your local Lincoln, Not activated Gun assembly is faulty. Repair or

Models: 215

1 35
Download 35 pages 59.91 Kb
Page 25
Image 25

 

E-2

 

TROUBLESHOOTING

 

E-2

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

PROBLEMS

 

POSSIBLE

RECOMMENDED

 

 

 

(SYMPTOMS)

 

CAUSE

COURSE OF ACTION

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

Major Physical or Electrical

1.

Contact your Local Lincoln

 

 

 

 

Damage is Evident

 

 

Authorized Field Service Facility.

 

 

 

 

There is no wire feed or open cir-

1

The gun trigger or cable may be

 

 

 

 

 

cuit voltage when the gun trigger is

 

faulty. Check or replace gun

 

 

 

 

pulled. Input power is applied to

2.

assembly.

 

 

 

 

POWER MIG 215.

 

The thermal protection circuit

 

 

 

 

 

 

 

may be activated. If this is the

 

 

 

 

 

 

 

case allowing the machine to

 

 

 

 

 

 

3.

cool will clear the error condition.

 

 

 

 

 

 

Make sure input voltage is cor-

 

 

 

 

 

 

 

rect and matches nameplate rat-

 

 

 

 

 

 

 

ing and reconnect panel configu-

 

 

 

 

 

 

4.

ration.

 

 

 

 

 

 

If spool gun option kit is in

 

 

 

 

 

 

 

stalled, check to see that it is set

 

 

 

 

 

 

 

to “Normal” if pulling the gun trig-

 

 

 

 

 

 

 

ger associated with built in feed-

 

 

 

 

 

 

 

er, and “Spool Gun” if pulling

If all recommended possible areas

 

 

 

 

 

spool gun trigger.

 

 

 

 

 

 

 

of misadjustment have been

 

 

 

Output voltage and wire feed is pre-

1.

Remove gun assembly from

 

 

 

checked and the problem persists,

 

 

sent when gun trigger is not pulled

 

machine. If problem is solved

Contact your local Lincoln

 

 

 

(not activated).

 

 

gun assembly is faulty. Repair or

Authorized Field Service Facility.

 

 

 

 

2.

replace.

 

 

 

 

 

 

If problem persists when gun

 

 

 

 

 

 

 

assembly is removed from

 

 

 

 

 

 

 

machine then the problem is

 

 

 

 

 

 

 

within the POWER MIG 215.

 

 

 

 

Machine output is low. Welds are

1.

Check input voltage. Make sure

 

 

 

 

 

“cold”, weld bead is rounded or

 

input voltage matches name-

 

 

 

 

bumped up demonstrating poor

 

plate rating and reconnect panel

 

 

 

 

wetting into plate.

 

2.

configuration.

 

 

 

 

 

 

Make sure settings for wire feed

 

 

 

 

 

 

 

speed and voltage are correct

 

 

 

 

 

 

3.

for process being used.

 

 

 

 

 

 

Make sure output polarity is cor-

 

 

 

 

 

 

4.

rect for process being used.

 

 

 

 

 

 

Check welding cables and gun

 

 

 

 

 

 

 

assembly for loose or faulty con-

 

 

 

 

 

 

 

nections.

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your LOCAL AUTHORIZED LINCOLN ELECTRIC FIELD SERVICE FACILITY for assistance before you proceed.

POWER MIG 215

Page 25
Image 25
Lincoln Electric 215 manual Contact your local Lincoln, Not activated Gun assembly is faulty. Repair or