Lincoln Electric F355I manual Safety Precautions, Select Suitable Location

Models: F355I

1 37
Download 37 pages 18.56 Kb
Page 11
Image 11

A-2

INSTALLATION

A-2

 

 

 

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK can kill.

Turn the input power off at the dis- connect switch before attempting to connect or disconnect input power lines, output cables or con- trol cables

Only qualified personnel should perform this installation.

Connect the green lead of the power cord to ground per National Electrical Code.

----------------------------------------------------------------------

CAUTION

Incorrect connection may result in equipment damage.

-----------------------------------------------------------------------

POWER CORD CONNECTION

A 7ft. (2m) power cord is provided and wired into the machine. Follow the power cord connection instruc- tions.

SELECT SUITABLE LOCATION

The Invertec POWER WAVE F355i will operate in harsh environments. Even so, it is important that sim- ple preventative measures are followed in order to assure long life and reliable operation.

The machine must be located where there is free cir- culation of clean air such that air movement in the back, out the sides and bottom will not be restricted.

Dirt and dust that can be drawn into the machine should be kept to a minimum. Failure to observe these precautions can result in excessive operating temperatures and nuisance shutdown.

Keep machine dry. Shelter from rain and snow. Do not place on wet ground or in puddles.

DO NOT MOUNT OVER COMBUSTIBLE SURFACES.

CAUTION

Where there is a combustible surface directly under stationary or fixed electrical equipment, that surface shall be covered with a steel plate at least .06”(1.6mm) thick, which shall extend not less than 5.90”(150mm) beyond the equipment on all sides.

-----------------------------------------------------------------------

STACKING

POWER WAVE F355i can not be stacked.

TILTING

Place the machine directly on a secure, level surface or on a recommended undercarriage. The machine may topple over if this procedure is not followed.

INPUT AND GROUNDING CONNECTIONS

Only a qualified electrician should connect the Invertec POWER WAVE F355i. Installation should be made in accordance with the appropriate National Electrical Code.

BLACK

GREEN/YELLOW

BLUE

BROWN

Three Phase Input

Connect green lead to ground per National Electric Code.

Connect black, red and white leads to power.

POWER WAVE F355i (CE)

Page 11
Image 11
Lincoln Electric F355I manual Safety Precautions, Select Suitable Location