A-5

INSTALLATION

A-5

 

 

 

WARNING

ELECTRIC SHOCK can kill.

Turn the input power OFF at the disconnect switch or fuse box before working on this equipment.

----------------------------------------------------------------------

1.Set the High/Low switch code on Feed Head PC board as follows:

2.Turn off power to the power source at the dis- connect switch.

3.Remove the front cover from the power source.

4.The wire feed head board is on the left side of the power source. Locate the 8-position DIP switch and look for position 8 of the DIP switch. (See Figure A.1)

5.Using a pencil or other small object, slide the switch to the OFF position, when the low speed gear is installed. Conversely, slide the switch to the ON position when the high speed gear is installed.

6.Replace the cover and screws. The PC board will “read” the switch at power up, automatically adjust- ing all control parameters for the speed range selected.

DIP Switch Settings and Locations

(See Figure A.1)

DIP switches on the P.C. Boards allow for custom configuration of the Power Wave. To access the DIP switches:

WARNING

Turn off power at the disconnect switch.

------------------------------------------------------------------------

Remove the top four screws securing the front access panel.

Adjust the DIP switches as necessary.

Replace the panel and screws, and restore power.

Control Board DIP Switch:

switch 1 = Object Instance LSB 1 (see table 1) switch 2 = Object Instance MSB 2 (see table 1) switch 3 = Equipment Group 1 Select

switch 4 = Equipment Group 2 Select switch 5 = Equipment Group 3 Select switch 6 = Equipment Group 4 Select switch 7 = reserved for future use switch 8 = work sense lead

1 LEAST SIGNIFICANT BIT

2 MOST SIGNIFICANT BIT

switch 8

work sense lead

off

work sense lead not connected*

on

work sense lead connected

Feed Head Board DIP Switch:

switch 1 = Object Instance LSB (see table 1) switch 2 = Object Instance MSB (see table 1) switch 3 = Equipment Group 1 Select switch 4 = Equipment Group 2 Select switch 5 = Equipment Group 3 Select switch 6 = Equipment Group 4 Select switch 7 = negative polarity switch

 

 

 

switch 7

 

electrode polarity

 

 

 

 

 

off

 

 

 

 

 

positive *

 

 

 

 

 

 

on

 

 

 

 

 

negative

 

 

 

 

 

 

 

 

switch 8 = high speed gear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

switch 8

 

wire drive gear

 

 

 

 

 

 

off

 

 

 

 

low speed gear *

 

 

 

 

 

on

 

 

 

 

high speed gear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 1

 

 

 

 

 

Object Instance

 

 

 

 

 

 

 

 

 

 

 

 

 

switch 2

 

switch 1

 

Instance

 

 

 

 

off

 

 

 

 

off

 

0 *

 

 

 

 

off

 

 

 

 

on

 

1

 

 

 

 

on

 

 

 

 

off

 

2

 

 

 

 

on

 

 

 

 

on

 

3

*Factory Setting

 

 

 

 

 

FEED HEAD BOARD DIP SWITCH

 

FIGURE A.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

7

6

5

4

3

2

1

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL BOARD DIP SWITCH

O

N

1 2 3 4 5 6 7 8

LOCATION OF DIP SWITCHES IN MACHINE

POWER WAVE F355i (CE)

Page 14
Image 14
Lincoln Electric F355I manual DIP Switch Settings and Locations, Control Board DIP Switch, Feed Head Board DIP Switch