TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
TROUBLESHOOTING GUIDE
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS |
| POSSIBLE |
| RECOMMENDED | ||||
(SYMPTOMS) |
| CAUSE |
| COURSE OF ACTION | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
| |
|
|
|
|
|
|
|
|
|
| Major physical or electrical damage | 1. Contact your local authorized |
|
|
| |||
| is evident when the sheet metal |
|
| Lincoln Electric Field Service |
|
|
|
|
| covers are removed. |
|
| facility for technical assis- |
|
|
|
|
|
|
|
| tance. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Input fuses keep blowing, or input |
|
| 1. Make certain that fuses or |
|
|
|
|
| breaker keeps tripping. |
|
| breakers are properly sized. |
|
|
|
|
|
|
|
| See Installation section of this |
|
|
|
|
|
|
|
| manual for recommended |
|
|
|
|
|
|
|
| fuse and breaker sizes. |
|
|
|
|
|
|
|
| 2. Welding procedure is drawing |
|
|
|
|
|
|
|
| too much output current, or |
|
|
|
|
|
|
|
| duty cycle is too high. |
|
|
|
|
|
|
|
| Reduce output current, duty |
|
| If all recommended possible areas |
|
|
|
|
| cycle, or both. |
|
|
| |
|
|
|
|
|
| of misadjustments have been |
| |
|
|
|
| 3. There is internal damage to |
|
|
| |
|
|
|
|
|
| checked and the problem persists, |
| |
|
|
|
| the power source. Contact an |
|
|
| |
|
|
|
|
|
| contact your local Lincoln |
| |
|
|
|
| authorized Lincoln Electric |
|
|
| |
|
|
|
|
|
| Authorized Field Service Facility. |
| |
|
|
|
| Service facility. |
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Machine will not power up (no |
|
| 1. Make certain that the Power |
|
|
|
|
| lights, no fan, etc.) |
|
| to the POWER WAVE F355i |
|
|
|
|
|
|
|
| (CE) is on. |
|
|
|
|
|
|
|
| 2. Circuit Breaker CB1 (on Case |
|
|
|
|
|
|
|
| Front) may have opened. |
|
|
|
|
|
|
|
| Reset. An over load on the |
|
|
|
|
|
|
|
| 40V Wire Feeder supply may |
|
|
|
|
|
|
|
| cause this to trip. |
|
|
|
|
|
|
|
| 3. Circuit breaker CB3 (in recon- |
|
|
|
|
|
|
|
| nect area) may have opened. |
|
|
|
|
|
|
|
| Reset. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION