Lincoln Electric IM463-A manual Operating Instructions, GMAW MIG Operation

Models: IM463-A

1 34
Download 34 pages 14.19 Kb
Page 15
Image 15
OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

GMAW (MIG) OperationWARNING

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground.

Always wear dry insulating gloves.

------------------------------------------------------------------------

FUMES AND GASES can be dangerous.

Keep your head out of fumes.

• Use ventilation or exhaust to remove

fumes from breathing zone.

------------------------------------------------------------------------

WELDING SPARKS can cause fire or Manual backgroundManual backgroundManual backgroundManual background explosion.

Keep flammable material away.

Do not weld on closed containers.

------------------------------------------------------------------------

ARC RAYS can burn eyes and skin.

Wear eye, ear and body protection.

------------------------------------------------------------

See additional warning information at front of this operator’s manual.

-----------------------------------------------------------

GMAW (MIG) Operation

Properly connect a wire feeder control cable to either the terminal strip or to the Wire Feeder Receptacle.

If welding electrode positive, connect the electrode cable to the “+” output studs. Connect the work cable to the center output studs, labeled “GMAW, FCAW”. Do not make any connections to the left hand pair of output studs.

Set the control panel switches as follows:

------------------------------------------------------------------------

Mode: GMAW

------------------------------------------------------------------------

Output Local or Remote (See “Output Control

Control: Switch”)

------------------------------------------------------------------------

LN-9/NA-5:Off, unless an LN-9 or NA-5 is being used.

------------------------------------------------------------------------

Wire Feeder Set to match the electrode polarity.

Voltmeter:

------------------------------------------------------------------------

Output

Terminals: Remote

------------------------------------------------------------------------

If using Local output control, preset the desired welding voltage using the Output potentiometer and the voltmeter. If using Remote Output control, preset the welding voltage using a remote control, or with the voltage control on the wire feeder. If using an LN-9, see “Operation with LN-9 or NA-5 Wire feeder” section.

Set up the wire feeder according to the wire feeder instruction manual.

When the gun trigger is pulled (or the weld sequence is started) and an arc is struck, the voltmeter will display the welding voltage preset at the output studs of the DC-650 PRO, and the ammeter will display the output current.

15

Page 15
Image 15
Lincoln Electric IM463-A manual Operating Instructions, GMAW MIG Operation