TROUBLESHOOTING
TROUBLE | CAUSE | WHAT TO DO | ||
|
|
|
|
|
E. Machine has low output and | 1. | Output control Local/Remote | 1. | Check position of switch. |
no control. |
| switch in wrong position. |
|
|
| 2. | Output control switch faulty. | 2. | Check switch and replace if faulty. |
| 3. | Fault in leads 75,76, or 77. | 3. | Check wiring. |
| 4. | Faulty Control P.C. Board. | 4. | Replace. See P.C. Board |
|
|
|
| Troubleshooting Procedure. |
| 5. | Output control potentiometer | 5. | Check and replace |
|
| circuit open (lead 75). |
| potentiometer if faulty. Check |
|
|
|
| wiring of lead #75. |
|
|
|
|
|
F. Machine does not have | 1. | One input fuse blown. | 1. | Check and replace if blown |
maximum output. |
|
|
| after checking for reason for |
|
|
|
| blown fuse. |
| 2. | One phase of main transformer | 2. | Check for open and repair. |
|
| open. |
|
|
| 3. | Faulty Control P.C. Board. | 3. | Replace. See P.C. Board |
|
|
|
| Troubleshooting Procedure. |
| 4. | Output control potentiometer. | 4. | Check and replace if faulty. |
| 5. | Output control potentiometer | 5. | Check and repair broken leads. |
|
| lead 75 open. |
|
|
| 6. | Defective main SCR bridge. | 6. | Check and replace if defective. |
|
|
|
|
|
G. Machine will not shut off. | 1. | Input contactor contacts frozen. | 1. | Check and replace if |
|
|
|
| necessary. |
| 2. | Defective On/Off switch, | 2. | Replace. |
|
|
|
|
|
H. Variable or sluggish welding | 1. | Poor work or electrode | 1. | Check & clean all connections. |
arc. |
| connection. |
|
|
| 2. | Welding leads too small. | 2. | Check table in instruction manual. |
| 3. | Welding current or voltage too | 3. | Check procedures for |
|
| low. |
| recommended settings. |
| 4. | Leads or connections open in control | 4. | Check & replace if defective. |
|
| circuit. |
|
|
| 5. | 5. | Only connect one pair of | |
|
|
|
| negative studs to the work. |
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.