TROUBLESHOOTING

TROUBLE

CAUSE

WHAT TO DO

 

 

 

 

 

E. Machine has low output and

1.

Output control Local/Remote

1.

Check position of switch.

no control.

 

switch in wrong position.

 

 

 

2.

Output control switch faulty.

2.

Check switch and replace if faulty.

 

3.

Fault in leads 75,76, or 77.

3.

Check wiring.

 

4.

Faulty Control P.C. Board.

4.

Replace. See P.C. Board

 

 

 

 

Troubleshooting Procedure.

 

5.

Output control potentiometer

5.

Check and replace

 

 

circuit open (lead 75).

 

potentiometer if faulty. Check

 

 

 

 

wiring of lead #75.

 

 

 

 

 

F. Machine does not have

1.

One input fuse blown.

1.

Check and replace if blown

maximum output.

 

 

 

after checking for reason for

 

 

 

 

blown fuse.

 

2.

One phase of main transformer

2.

Check for open and repair.

 

 

open.

 

 

 

3.

Faulty Control P.C. Board.

3.

Replace. See P.C. Board

 

 

 

 

Troubleshooting Procedure.

 

4.

Output control potentiometer.

4.

Check and replace if faulty.

 

5.

Output control potentiometer

5.

Check and repair broken leads.

 

 

lead 75 open.

 

 

 

6.

Defective main SCR bridge.

6.

Check and replace if defective.

 

 

 

 

 

G. Machine will not shut off.

1.

Input contactor contacts frozen.

1.

Check and replace if

 

 

 

 

necessary.

 

2.

Defective On/Off switch, S-1.

2.

Replace.

 

 

 

 

 

H. Variable or sluggish welding

1.

Poor work or electrode

1.

Check & clean all connections.

arc.

 

connection.

 

 

 

2.

Welding leads too small.

2.

Check table in instruction manual.

 

3.

Welding current or voltage too

3.

Check procedures for

 

 

low.

 

recommended settings.

 

4.

Leads or connections open in control

4.

Check & replace if defective.

 

 

circuit.

 

 

 

5.

LN-9/NA-5 switch in wrong position.

5.

Only connect one pair of

 

 

 

 

negative studs to the work.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

21

Page 21
Image 21