TROUBLE

CAUSE

WHAT TO DO

 

 

 

 

 

I. Output control not functioning

1.

Output control switch in wrong

1.

Place switch in “Local” position.

on the machine.

 

position.

 

 

 

2.

Faulty output control switch.

2.

Check & replace if found faulty.

 

3.

Faulty output control

3.

Check & replace if found faulty.

 

 

potentiometer.

 

 

 

4.

Leads or connections open in

4.

Check lead continuity and

 

 

control circuit.

 

connections for an open and

 

 

 

 

repair if necessary.

 

5.

LN-9/NA-5 switch in wrong

5.

Set to “Off” when not using an

 

 

position.

 

LN-9/NA-5.

 

6.

Faulty Control P.C. Board.

6.

Replace. See P.C. Board

 

 

 

 

Troubleshooting Procedure.

 

 

 

 

 

J. Output control not functioning

1.

Output control switch in wrong

1.

Place switch in “Output Control

on remote control.

 

position.

 

Remote”.

 

2.

Faulty output control switch.

2.

Check & replace if found faulty.

 

3.

Faulty remote control

3.

Check & replace if found faulty.

 

 

potentiometer.

 

 

 

4.

Leads or connections open in

4.

Check all leads and

 

 

control circuit.

 

connections, internal or remote,

 

 

 

 

for continuity; repair if

 

 

 

 

necessary.

 

5.

Faulty Control P.C. Board.

5.

Replace. See P.C. Board

 

 

 

 

Troubleshooting Procedure.

 

 

 

 

 

K. Digital meters do not light

1.

Faulty Meter P.C. Board.

1.

Replace. See P.C. Board

 

 

 

 

Troubleshooting Procedure.

- or -

 

 

 

 

 

2.

Faulty Control P.C. Board.

2.

Replace. See P.C. Board

Digital meter display is

 

 

 

Troubleshooting Procedure.

incorrect.

 

 

 

 

 

3.

Secondary thermostat is open.

3.

See “Thermostatic Protection”

 

 

 

 

section.

 

 

 

 

 

L. Poor arc striking with

1.

Poor work connection.

1.

Work connection must be

semiautomatic wire feeders.

 

 

 

adequate for application.

 

2.

Improper procedures.

2.

Adjust procedures for improved

 

 

 

 

starting.

 

3.

Defective P.C. Board.

3.

Replace. See P.C. Board

 

 

 

 

Troubleshooting Procedure.

 

 

 

 

 

22