A-12

INSTALLATION
POWER FEED 10

A-12

Magnum 200 / 300 / 400 Guns

The easiest and least expensive way to use Magnum
200/300/400 guns with the Power Feed 10 wire feeder
is to order them with the K466-10 connector kit, or to
buy a completely assembled Magnum gun having the
K466-10 connector (such as the K497-21 dedicated
Magnum 400).

Magnum 550 Guns

The easiest and least expensive way to use the
Magnum 550 guns with Power Feed 10 wire feeders
is to order the gun with the K613-7 connector kit, and
install a K1500-3 gun connection kit to the wire feeder.

Lincoln Innershield and Sub Arc Guns

All of these guns can be connected to the Power Feed
by using the K1500-1 Adapter Kit.

Lincoln Fume Extraction Guns

The K556 (250XA) and K566 (400XA) guns require
that a K489-2 Fast-Mate™ adapter kit be installed.
Installation of this adapter also requires a K1500-1
gun connector kit.
The K206, K289, and K309 require only the installa-
tion of a K1500-1 connector in the Power Feed wire
feeder.

Non-Lincoln Guns

Most competitive guns can be connected to the Power
Feed by using one of the K1500 series adapter kits,
See “Gun Adapters” in ACCESSORIES section.
GENERAL GUN CONNECTIONGUIDELINES

GUN CONNECTIONS - GENERAL

4-roll feed plates are equipped with a brass connector
bar at the gun-end of the feed plate to allow a bolted
brass-to-brass electrical connection to be made direct-
ly to either standard or Fast-mate gun adapter bush-
ings. Use a 1/4 inch allen key on the factory-installed
socket head cap screw to insure that the connector
bar is securely tightened to the adapter bushing.
The instructions supplied with the gun and K1500
series gun adapter should be followed when installing
and configuring a gun. What follows are some gener-
al guidelines that are not intended to cover all guns.
a. Turn off input power at welding power source
before installation or changing of gun.
b. Check that the drive rolls and guide tubes are
proper for the electrode size and type being used.
If not, change them.
c. Lay the cable out straight. Insert the connector
on the welding conductor cable into the brass
conductor block on the front of the wire drive
head. Make sure it is all the way in and tighten
the hand clamp. Keep this connection clean and
bright. Connect the trigger control cable polarized
plug into the mating 5 cavity receptacle on the
front of the wire drive unit.
Note:for Fast-Mate and European connector style
guns, connect gun to gun connector making
sure all pins and gas tube line up with appropri-
ate holes in connector. Tighten gun by turning
large nut on gun clockwise.
d. For GMA Gun Cables with separate gas fittings,
connect the 3/16” I.D. gas hose from the wire
drive unit to the gun cable barbed fitting.
e. For water cooled guns see WATER CONNEC-
TIONS in this section.