TROUBLESHOOTING

 

E-9

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE CAUSE

 

RECOMMENDED

 

 

(SYMPTOMS)

 

COURSE OF ACTION

 

 

 

 

17.

Dual Procedure is not function-

a. Faulty local dual procedure

 

 

 

ing when using the local dual

switch or Circuit Boards mother

 

 

 

procedure switch (on Circuit

board. Disconnect harness plug

 

 

 

Boards). Status lights are solid

from J5 of Circuit Board mother

 

 

 

green on Circuit Boards and

board. Check that there is conti-

 

 

 

Head boards.

nuity between plug pins 1 and 7

 

 

 

 

 

local DPS is in position “A” but

 

 

 

 

 

not when in gun or “B”. Now

 

 

 

 

 

check that there is continuity

 

 

 

 

 

between plug pins 1and 8 when

 

 

 

 

 

local DPS is in position “B” but

 

 

 

 

 

not when in “Gun” or “A”. If any

 

 

 

 

 

of these continuity tests fail,

 

 

 

 

 

repair or replace switch or switch

 

 

 

 

 

harness to correct the problem,

 

 

 

 

 

Otherwise, replace CB mother

 

 

 

 

 

board.

 

 

 

 

 

 

If all recommended possible areas of

18.

Wire feed speed is consistent

a. Dip switch on feed head board

 

 

and adjustable, but operates at

does not match gear ratio used at misadjustment have been checked

 

the wrong speed.

gear box. If using a high speed

 

and the problem persists, Contact

 

 

 

gear, the feed head PC board dip

 

your local Lincoln Authorized

 

 

 

switch 8 must be set to 1 or “ON”. Field Service Facility.

 

 

 

b. Feed head board is not properly

 

 

 

 

 

reading DIP switch. Replace feed

 

 

 

 

 

head PC board.

 

 

19. Status LED not solid green

a. see LED Status Light Chart.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER FEED 10

Page 56
Image 56