C-2

ACCESSORIES

C-2

 

 

 

DESCRIPTION AND INSTALLATION OF OPTIONAL CONTROL BOX PANELS

A number of Optional Features are available for use with Power Feed 10. Some Installation information is provided in this section. REFER TO THE INSTRUC-

TIONS THAT COME WITH EACH KIT FOR DETAILED INFORMATION REGARDING INSTALLA- TION.

OPTIONAL PANELS FOR CONTROL BOX

All optional panels for the control box are described in the ACCESSORIES section of this manual along with their installation instructions as are all other pieces of optional equipment.

The PF-10 Control Box is designed to accept three control panels, two ʻlargeʼ and one “small” panels are needed to make up a complete control panel for the Control Box. Panels can be mounted in one of three positions: upper, middle and lower.

Each Control Box is shipped with a Control/Display (CD) panel, a large panel, installed in the upper posi- tion, and a CV/Gouge (CV/G) panel (another large panel) in the lower position. The middle position is filled with a blank panel.

The CD panel must be installed in every Control Box. The small panel can be blank, it can be a Dual Procedure panel, or a Dual Procedure Memory panel. The remaining large panel can be one of the following: CV/G, M, MX2, or MSP2. The features of each are described in the Operation section of this manual.

There are extra mounting holes in the upper and mid- dle positions which allow the upper two panels to be interchanged. (Instead of the upper, middle and lower panels being large, small and large, they could be installed in the order small, large, large.) This may be done for convenience sake, or to take advantage of the Large Security Door option.

Note: The CD panel must be installed in either the middle or the upper position; its harness is not long enough to allow installation in the lower position.

GENERAL PANEL INSTALLATION GUIDELINES:

Installation or removal of any panel can be done with only a Phillips screwdriver after the system power is turned off. To remove a panel, remove the two screws holding it in place, remove the push-on chassis ground wire and remove the harness connection to the Control Box main PC board. To install any panel, reverse that process. Turn power back on when com- plete (option panels are only recognized at power up. Do not install panels with the power on.) Note that removal or installation of any panel may also require the removal of the other panel, in order to have easy access to the PC board connectors. Detailed installa- tion instructions are shipped with each option panel.

K1542-5 DUAL PROCEDURE PANEL

The Dual Procedure Panel provides a fixed large bat toggle switch or the use of a gun switch for the selec- tion of either of two procedures. The upper position of the bat switch selects PROCEDURE A, while the lower selects PROCEDURE B. The middle position selects the GUN switch, in which case the procedure is determined by the position of the switch located at the gun.

NOTE: Due to the nature of fixed position switches, this option does not allow the indication of a remotely selected procedure. When in the gun mode there is no prevision to indicate, at the Control Box, which procedure has been remotely selected (at the gun) .

Installation is as follows:

1.Turn off power.

2.Remove the two screws from the front of the standard or option panel at the location you choose to install your new option, (middle), of the Control Box cabinet. Save the screws for re-use. Unplug the white electrical con- nector. Remove the chassis wire (if equipped) from the back of the standard or option panel. Discard the old panel or save for future use.

3.Tilt the new option panel away from the front opening of the Control Box cabinet and plug the white electrical connector into the proper connector on the right side of the main printed circuit board (10 pin) until the connec- tor latches into place. Attach the chassis wire (if equipped) to the back of the new panel.

4.Slide the new panel through the opening, taking care not to damage the connections and the printed circuit board on the back.

5.Align the screw holes. Replace the two screws and tighten.

POWER FEED 10

Page 36
Image 36