C-9

ACCESSORIES

C-9

 

 

 

LINC NET RECEPTACLE (INPUT)

Power Feed Wire Feeder Optional Input Connector Installation into the Control Box Cabinet and Conversion to Fixture Wire Feeder

1.Turn off power.

2.Remove the screws from the front of the lower and middle option panels of the Control Box cabi- net.

3.Tilt the option panels away from the front opening of the Control Box cabinet. If the option panel has an electrical connector, disconnect it from the main printed circuit board (note connection point for re-connection later). Remove the option panel and set aside.

4.Disconnect the connector located at the back wall of the Control Box cabinet.

5.Loosen (do not remove) the four screws located on the back wall of the Control Box cabinet.

6.Lift Control Box cabinet off of the four screws loosened above and set on a work surface. Re- tighten the four screws to secure for future use.

7.Remove the plastic plug (black) from the right hole in the bottom wall of the Control Box cabinet and insert it into the hole in the front of the Feeder Head.

8.Place the Optional Input Connector (Amphenol) through the hole opened by the previous step (place from the inside, out). Rotate the Optional Input Connector so itʼs aligning key is positioned to the front of the Control Box cabinet. Fasten the Optional Input Connector to the bottom wall of the Control Box cabinet with the four screws provided and connect the optionʼs opposite end to the con- nector referred to in step 4.

9.Secure the choke (large circular component of the Optional Input Connector) by inserting itʼs leads into the white nylon clip located near the Optional Input Connector on the back wall of the Control Box cabinet. Insert the choke leads only.

10.Install an Optional Output Connector (Lincoln stock # K1549-1) into the Control Box cabinet, if not already present.

11.Mount the Control Box cabinet to the work station fix- ture at this time, if desired. The four holes in the back wall of the Control Box cabinet can be used for this purpose.

12.Re-install the lower and middle option panels by reversing the removal process. While re-installing the option panels, ensure clearance between Optional Input Connector components, Control Box wiring harness, and option panel wiring har- ness (if any).

K162H - WIRE SPINDLE ADAPTER

Spindle for boom mounting Readi-Reels and 2” (51

mm)I.D. spools with up to 60 lb. (27.2 kg) capacity. User mounted to appropriately prepared boom frame- work. Includes an easily adjustable friction brake for control of overrun (a 2” spindle is standard on Power Feed 10 Bench model).

When a 2” (51 mm) spindle is used with Readi-Reels, or coils not on 12” (305 mm) O.D. spools, an adapter is required:

K1504-1 - COIL ADAPTER

Permits 50 lb to 60 lb (22.7-27.2 Kg.) coils to be mounted on 2” (51 mm) O.D. spindles.

K435 - COIL ADAPTER

Permits 14 lb. (6 kg) Innershield coils to be mounted on 2” (51 mm) O.D. spindles.

K363P - READI-REEL ADAPTER

Adapts Lincoln Readi-Reel coils of electrode 30 lb. (14 kg) and 22 lb. (10 kg) to a 2” (51 mm) spindle. Durable molded plastic one piece construction. Designed for easy loading; adapter remains on spin- dle for quick changeover.

K438 - READI-REEL ADAPTER

Adapts Lincoln Readi-Reel coils of electrode 50-60 lb. (22.7-27.2 kg) to a 2” (51 mm) spindle

POWER FEED 10

Page 43
Image 43
Lincoln Electric IM584-D K162H Wire Spindle Adapter, K1504-1 Coil Adapter, K435 Coil Adapter, K363P READI-REEL Adapter