C-7

ACCESSORIES

C-7

 

 

 

SAVE - The save mode allows “hard” memories to be changed. Pressing the SAVE key will light the save indicator, and enter the save mode. In the save mode, the indicator for the memory that was the source of the active procedureʼs contents will blink, whether their contents are still equal or not. This feature allows the user to choose to save an active procedure back to its source, or some other location.

To complete the save transaction requires the selec- tion of one of the memory keys. When the memory key is pressed in the save mode, itʼs contents are overwritten with the contents of the active procedure. This means that the contents of the memory location and the active procedure are now equal, and there- fore, by definition, each of their indicators will be lit, and the save mode will be exited. To exit the save mode without saving, depress the save key a second time. This feature allows the operator to determine the source of the active procedureʼs contents without actually overwriting it.

Installation is as follows:

1.Turn off power.

2.Remove the two screws from the front of the stan- dard or option panel at the location you choose to install your new option, (middle), of the Control Box cabinet. Save the screws for re-use. Unplug the white electrical connector. Remove the chas- sis wire (if equipped) from the back of the stan- dard or option panel. Discard the old panel or save for future use.

3.Tilt the new option panel away from the front opening of the Control Box cabinet and plug the white electrical connector into the proper connec- tor on the right side of the main printed circuit board (10 pin) until the connector latches into place. Attach the chassis wire (if equipped) to the back of the new panel.

4.Slide the new panel through the opening, taking care not to damage the connections and the print- ed circuit board on the back.

5.Align the screw holes. Replace the two screws and tighten.

K1543, K1544 AND K1545 INPUT CABLE ASSEMBLIES

Available Cable Assemblies:

K1543 - Control cable only. Consists of a 5-conductor control cable with a 5-pin control cable plug, without electrode cable, and is available in lengths of 8'(2.4m), 16'(4.9m), 25'(7.6m), 50'(15.2m) and 100'(30.5m).

K1544 - Consists of a 5-conductor control cable with a 5-pin control cable plug and a 4/0 electrode cable. It is rated at 600 amps, 60% duty cycle and is available in lengths of 8'(2.4m), 16'(4.9m), 25'(7.6m), 50'(15.2m).

K1545 - Control cable and a 4/0 (85 mm2) electrode cable with Twist-Mate™ connector on one end and a stud terminal on the other. It is rated at 500 amps, 60% duty cycle and is available in lengths of 8'(2.4m), 16'(4.9m), 25'(7.6m), 50'(15.2m).

With input power disconnected from the power source, install the Control Cable Assemblies per the instruction in INSTALLATION - “Cable Connections”.

POWER FEED 10

Page 41
Image 41
Lincoln Electric IM584-D manual K1543, K1544 and K1545 Input Cable Assemblies