Lincoln Electric IM679-A manual Possible Areas, Symptoms, Contact your Local Lincoln, Facility

Models: IM679-A

1 40
Download 40 pages 51.72 Kb
Page 24
Image 24

E-2

 

 

TROUBLESHOOTING

 

 

E-2

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

Major physical or electrical damage

1. Contact your local authorized

 

 

 

 

 

is evident when the sheet metal

Lincoln Electric Field Service facil-

 

 

 

 

 

covers are removed.

ity for technical assistance.

 

 

 

 

Input fuses keep blowing, or input 1. Make certain that the fuses or

breaker keeps trippingbreakers are properly sized. See installation section of the manual for recommended fuse and break- er sizes.

2.Welding procedure is drawing too much output current, or duty cycle is too high. Reduce output current, duty cycle or both.

3.There is internal damage to the power source. Contact an autho- rized Lincoln Electric Service facil- ity.

Machine will not power up (No 1. Make certain that the power

 

 

 

 

lights)

switch is in the "ON" position.

 

 

 

 

 

2. The circuit breaker in the recon- 1.If all recommended possible

areas

 

nect area may have opened.

of misadjustment have

been

 

Reset. Check input voltage sec-

checked and the problem persists,

 

tion below.

Contact your

local

Lincoln

 

3. Input voltage selection made

Authorized

Field

Service

 

improperly. Power down, check

Facility.

 

 

 

 

input voltage reconnect according

 

 

 

 

 

to diagram on reconnect cover.

 

 

 

 

Machine wont weld, cant get any 1. If the displays show an Err ###

output.see the fault section for corrective action.

2.If the displays are not lit refer to machine will not power up section.

3.If the thermal symbol is lit refer to the thermal section.

4.If the output terminals are in Remote control switch to "ON" and check for output voltage. If output voltage is now present check for correct remote control connection and operation.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

V350-PRO

Page 24
Image 24
Lincoln Electric IM679-A manual Possible Areas, Symptoms, Contact your Local Lincoln, Authorized Field Service, Facility