| TROUBLESHOOTING |
|
|
| ||
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
| |
|
|
|
| |||||
Displays | Description |
|
| |||||
|
|
| ||||||
Scrolling dash | Appears at power up while the machine is going through its self configu- | |||||||
|
|
|
| ration |
|
| ||
|
|
| ||||||
"Err" "####" | Fault code display. The first fault to occur will be displayed for three | |||||||
|
|
|
| seconds. The display will cycle through fault codes for all faults that | ||||
|
|
|
| persist after the initial | ||||
|
|
|
| ond each. |
|
| ||
|
|
|
|
| ||||
| Weld mode is changing |
|
| |||||
|
|
|
|
| ||||
| A constant voltage weld mode is selected, machine output is off. |
|
| |||||
|
|
|
| The numeric value in the right display is the workpoint. |
|
| ||
|
|
|
|
| ||||
"####" |
| A constant current weld mode is selected, machine output is off. |
|
| ||||
|
|
|
| The numeric value in the left display is either the workpoint or a |
|
| ||
|
|
|
| workpoint limit, depending on the weld mode and remote configura- | ||||
|
|
|
| tion. |
|
| ||
|
| |||||||
"####" "####"(on steady) | machine output is on. Left display is current, right display is voltage. | |||||||
|
|
|
| If actively welding, the displays are arc current and arc voltage. If | ||||
|
|
|
| not actively welding, the display will show workpoint. |
|
| ||
|
|
|
| |||||
"####" "####" (blinking) | weld just finished – the average arc voltage and current will be |
|
| |||||
|
|
|
| blinked for 5 seconds following a weld. If the workpoint changes dur- | ||||
|
|
|
| ing this 5 second period, the display will revert to the above mode. | ||||
|
|
|
|
|
|
|
|
|
CAUTION