TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
ARCLINK SYSTEM ERROR CODES
Err 33 | Capacitor bank "B" under | 1. | The power source input power |
| |||
| voltage. |
| may be wired incorrectly. Verify |
| |||
|
|
|
| the power | source reconnect |
| |
|
|
|
| panel wiring matches the input |
| ||
|
|
|
| power. |
|
|
|
|
|
| 2. | See the power source Instruction |
| ||
|
|
|
| Manual. |
|
|
|
|
|
|
|
| |||
Err 34 | Capacitor bank "A" overvolt- | 1. | The power source input power |
|
| ||
| age. |
| may be wired incorrectly. Verify |
| |||
|
|
|
| the power | source reconnect |
| |
|
|
|
| panel wiring matches the input |
| ||
|
|
|
| power. |
|
|
|
|
|
| 2. | See the power source Instruction |
| ||
|
|
|
| Manual. |
|
|
|
|
|
|
|
| |||
Err 35 | Capacitor bank "B" overvolt- | 1. | The power source input power |
|
| ||
| age. |
| may be wired incorrectly. Verify |
| |||
|
|
|
| the power | source reconnect | If all recommended possible areas of | |
|
|
|
| panel wiring matches the input | |||
|
|
|
| power. |
| misadjustment have been checked | |
|
|
|
|
|
| and the problem persists, Contact | |
|
|
| 2. | See the power source Instruction | your local Lincoln Authorized | ||
|
|
|
| Manual. |
| Field Service Facility. | |
|
|
|
|
| |||
Err 36 | Thermal | 1. | Power source overheating. Verify |
|
| ||
|
|
|
| duty cycle is correct. Ensure ade- |
| ||
|
|
|
| quate airflow around power |
| ||
|
|
|
| source. |
|
|
|
|
|
|
|
| |||
Err 41 | Long term secondary over- | 1. | The power source has exceeded |
|
| ||
| current. |
| the output current limits. Adjust |
| |||
|
|
|
| the welding procedure to reduce |
| ||
|
|
|
| the current draw. The welding |
| ||
|
|
|
| procedure | may exceed the |
| |
|
|
|
| capacity of the power source. |
| ||
|
|
| 2. | See the power source Instruction |
| ||
|
|
|
| Manual. |
|
|
|
|
|
|
|
| |||
Err 43 | Capacitors are out of bal- | 1. | Verify the power source recon- |
|
| ||
| ance |
| nect panel wiring matches the |
| |||
|
|
|
| input power. |
|
|
|
|
|
| 2. | See the power source Instruction |
| ||
|
|
|
| Manual. |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| CAUTION |
| ||
|
|
|
|
|
|
|
|
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.