E-3

TROUBLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

ARCLINK SYSTEM ERROR CODES

Err 33

Capacitor bank "B" under

1.

The power source input power

 

 

voltage.

 

may be wired incorrectly. Verify

 

 

 

 

 

the power

source reconnect

 

 

 

 

 

panel wiring matches the input

 

 

 

 

 

power.

 

 

 

 

 

 

2.

See the power source Instruction

 

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

Err 34

Capacitor bank "A" overvolt-

1.

The power source input power

 

 

 

age.

 

may be wired incorrectly. Verify

 

 

 

 

 

the power

source reconnect

 

 

 

 

 

panel wiring matches the input

 

 

 

 

 

power.

 

 

 

 

 

 

2.

See the power source Instruction

 

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

Err 35

Capacitor bank "B" overvolt-

1.

The power source input power

 

 

 

age.

 

may be wired incorrectly. Verify

 

 

 

 

 

the power

source reconnect

If all recommended possible areas of

 

 

 

 

panel wiring matches the input

 

 

 

 

power.

 

misadjustment have been checked

 

 

 

 

 

 

and the problem persists, Contact

 

 

 

2.

See the power source Instruction

your local Lincoln Authorized

 

 

 

 

Manual.

 

Field Service Facility.

 

 

 

 

 

Err 36

Thermal

1.

Power source overheating. Verify

 

 

 

 

 

 

duty cycle is correct. Ensure ade-

 

 

 

 

 

quate airflow around power

 

 

 

 

 

source.

 

 

 

 

 

 

 

 

Err 41

Long term secondary over-

1.

The power source has exceeded

 

 

 

current.

 

the output current limits. Adjust

 

 

 

 

 

the welding procedure to reduce

 

 

 

 

 

the current draw. The welding

 

 

 

 

 

procedure

may exceed the

 

 

 

 

 

capacity of the power source.

 

 

 

 

2.

See the power source Instruction

 

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

Err 43

Capacitors are out of bal-

1.

Verify the power source recon-

 

 

 

ance

 

nect panel wiring matches the

 

 

 

 

 

input power.

 

 

 

 

 

 

2.

See the power source Instruction

 

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

Page 33
Image 33
Lincoln Electric IM849 manual Your local Lincoln Authorized, Field Service Facility