B-10

OPERATION

B-10

 

 

 

GENERAL SETUP MODE OPTIONS

The Setup Mode can be used to set more general welding configurations such as travel options or dis- play configurations and can be used to access diag- nostic tools.

The POWER FEED™ 10A CONTROLLER can be configured to display the wire feed speed in inches per minute or meters per minute, and\or display wire feed speed or Amps in any weld mode. To access the wire feed speed units in the Setup Mode, enter into the Setup Mode by pressing both Mode Select Panel Pushbuttons simultaneously. The SETUP LED will illuminate. Turn the Mode Select Panel Knob until WFS UNITS is listed.

P.1

English

SETUP

 

 

 

 

 

 

WFS Units

 

 

 

 

Pressing the right Mode Select Panel Pushbutton will enter into the Travel Options. Turning the Mode Select Panel Knob will toggle between TRAVEL STARTS and TRAVEL STOPS. Pressing the right Mode Select Panel Pushbutton, will allow the travel to be set to start on the START BUTTON or on the ARC STRIKE, and to stop on the STOP BUTTON or on the ARC OUT.

P.12

Start

 

Button

SETUP

 

 

Travel Starts

 

 

 

 

P.12 Out

SETUP

Arc

 

 

 

Travel Ends

 

 

 

Press the right Mode Select Button.

Turn the Knob to toggle between English and Metric.

To set the display to read Wire Feed Speed or Amps, turn the Mode Select Knob until ARC DISPLAY MODE is listed.

P.2

Amps

SETUP

 

 

 

 

 

 

Arc Display Mode

 

 

 

 

Press the right Mode Select Button.

Turn the Knob to toggle between Amps or WFS.

The POWER FEED™ 10A CONTROLLER can start and stop travel based on the START and STOP Pushbuttons, or based on the arc being established or extinguished. To access the Travel Options in the Setup Mode, enter into the Setup Mode by pressing both Mode Select Panel Pushbuttons simultaneously. The SETUP LED will illuminate. Turn the Mode Select Panel Knob until TRAVEL OPTIONS is listed.

P.12

Travel

 

 

Options

 

SETUP

 

 

 

 

 

 

Yes

 

 

 

 

 

This item allows the user to reset the consumable weight to the initial weight set in Production Monitoring. This option only appears in the list when Production Monitoring is installed in the system.

P.14 Reset

Wire?

Yes

Press the right Mode Select Button to reset, left to cancel.

P.15 Enabled

Touch Sense

Press the right Mode Select Button.

Turn the Knob to toggle between Enabled or Disabled.

This option allows the user to enable or disable touch sense when inching down the wire.

Disabled = Default behavior, touch sense is disabled while inching down.

Enable= Touch sensing is enabled while inching down.

POWER FEED™ 10A CONTROLLER

Page 25
Image 25
Lincoln Electric IM849 manual General Setup Mode Options