B-9

 

 

OPERATION

B-9

 

 

 

 

 

 

 

 

WELD SEQUENCE PARAMETER LIST

 

 

 

 

 

 

PARAMETER

UNITS

RANGE

DEFAULT VALUE

WHERE IS IT SET?

 

 

 

 

 

Arc Delay Time

seconds

0-5.0

OFF

MSP4 - START OPTIONS

 

 

 

 

 

Strike Fault Time

seconds

0-10.0

OFF

MSP4- SETUP Menu

 

 

 

 

 

 

 

Strike WFS

IPM

from weld table*

weld mode dependant

Left Dual Display

 

 

 

 

 

 

 

Strike Volts

volts

from weld table*

weld mode dependant

Right Dual Display

 

 

 

 

 

 

 

Restrike Time

seconds

0-10.0

OFF

MSP4 - SETUP Menu

 

 

 

 

 

Start WFS/Amps

IPM/amperes

from weld table*

weld mode dependant

Left Dual Display

 

 

 

 

 

 

 

Start Volts

volts

from weld table*

weld mode dependant

Right Dual Display

 

 

 

 

 

 

 

Start Time

seconds

0-0.5

0.1

MSP4 - START OPTIONS

 

 

 

 

 

Start Arc Force

amperes

from weld table*

weld mode dependant

MSP4 - SETUP Menu

 

 

 

 

 

 

 

Upslope Time

seconds

0-10.0

OFF

MSP4 - SETUP Menu

 

 

 

 

 

Weld WFS/Amps

IPM/amperes

from weld table*

weld mode dependant

Left Dual Display

 

 

 

 

 

 

 

Weld Volts

volts

from weld table*

weld mode dependant

Right Dual Display

 

 

 

 

 

Weld Arc Force

amperes

from weld table*

weld mode dependant

MSP4 - SETUP Menu

 

 

 

 

 

Frequency (AC)

hertz

10-100

weld mode dependant

AC CONTROL

 

 

 

 

 

 

 

Balance (AC)

percent

25-75

weld mode dependant

AC CONTROL

 

 

 

 

 

 

 

Offset (AC)

percent

-50.0 - +50.0

0.0

AC CONTROL

 

 

 

 

 

Arc 2 Phase (if applicable)

degrees

0-359

90

AC CONTROL

 

 

 

 

 

Arc 2 Balance (if applicable)

percent

25-75

50

AC CONTROL

 

 

 

 

 

Arc 3 Phase (if applicable)

degrees

0-359

180

AC CONTROL

 

 

 

 

 

Arc 3 Balance (if applicable)

percent

25-75

50

AC CONTROL

 

 

 

 

 

Arc 4 Phase (if applicable)

degrees

0-359

270

AC CONTROL

 

 

 

 

 

Arc 4 Balance (if applicable)

percent

25-75

50

AC CONTROL

 

 

 

 

 

Downslope Time

seconds

0-10.0

OFF

MSP4 - SETUP Menu

 

 

 

 

 

Crater WFS/Amps

IPM/amperes

from weld table*

weld mode dependant

Left Dual Display

 

 

 

 

 

 

 

Crater Volts

volts

from weld table*

weld mode dependant

Right Dual Display

 

 

 

 

 

 

 

Crater Time

seconds

0-10.0

OFF

END OPTIONS

 

 

 

 

 

Crater Arc Force

amperes

from weld table*

weld mode dependant

MSP4 - SETUP Menu

 

 

 

 

 

Burnback Time

seconds

0-2.0

0.2

END OPTIONS

 

 

 

 

 

 

* Range depends on the Machine Power Source, Literature and Tables supplied with each unit.

POWER FEED™ 10A CONTROLLER

Page 24
Image 24