OPERATION | ||
|
|
|
6.WIRE SIZE SELECT SWITCH: This toggle switch selects between electrode diameters of .035” (1
mm)and smaller or .045” (1.2 mm) and larger. The
.035” (1 mm) position provides improved perfor- mance of smaller diameter wires at higher wire feed speeds.
7.WIRE TYPE SELECT SWITCH: This toggle switch selects between mild or stainless steel. In the stain- less position, the pulse width of the Peak Current is changed from 1 to 2 ms for better performance for stainless steel welding.
8.THERMAL
sor has actuated. Machine output will return after the internal components have returned to normal operating temperature (if the thermostat(s) “opened”) or after about
9.REMOTE RECEPTACLE: This is a 10 pin MS- type connector for remote control of Peak Current and Background Current. Trigger switch connec-
tions are also provided. The presence of the mating connec- tor is automatically sensed, disabling the front panel Peak and Background Current controls. Refer to “REMOTE CON- TROL CONNECTOR” in the ACCESSORIES Section of this manual for more information.
10.WIRE FEEDER RECEPTACLE: This is 14
pin
the trigger switch connections are provided. (Only 42 VAC is available on European models). There are no provisions for voltage control of the power source by the wire feeder. Refer to the Accessories section of this manual for wire feeder connection instructions.
11.ARC SENSE RECEPTACLE: This is a four pin
12.42V AUXILIARY POWER CIRCUIT BREAKER: The 42 VAC supply is protected from exces-
sive current draws with a 6 amp circuit break- er. When the breaker “trips” its button will extend. Depressing this button will reset the breaker.
13.115V AUXILIARY POWER CIRCUIT BREAKER
(Not on European Models): The 115 VAC supply is protected from excessive current draws with a 6 amp circuit breaker. When
the breaker “trips” its button will extend. Depressing this button will reset the breaker.
14.WORK TERMINAL: This
15.ELECTRODE TERMINAL: This twist- mate connection is the positive output ter- minal for connecting an electrode cable to the wire feeder conductor block. Refer to
the Accessories Section for wire feeder connection instructions.
WELDING OPERATION
Familiarize yourself with the controls on the INVERTEC STT II (CE) before beginning to weld.
Familiarize yourself with the operating manual for the wire feeder and the wire feeder controls before begin- ning to weld.
Set the Wire Size and Wire Type selection switches per the appropriate wire. Refer to “Operational Features and Controls” in this section for the function of these switches.
INVERTEC STT II (CE)