INSTALLATION |
TECHNICAL SPECIFICATIONS –INVERTEC STT II (CE) (For Code 11366)
INPUT- THREE PHASE ONLY
STANDARD VOLTAGE
INPUT CURRENT AT RATED OUTPUT
200/220/380/415/440/3/50/60 HZ
33/30/18/17/16
RATED OUTPUT
DUTY CYCLE |
|
|
|
| AMPS |
|
| VOLTS AT RATED AMPS | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
60% Duty Cycle |
|
|
| 225 |
|
|
|
|
|
| 29 |
| ||
100% Duty Cycle |
|
|
| 200 |
|
|
|
|
|
| 28 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OUTPUT |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |||
CURRENT RANGE |
| OPEN CIRCUIT VOLTAGE |
| AUXILIARY POWER | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||
Peak Current 1 0 - 450 Amps |
|
| 85 VDC Maximum |
| 115 2 VAC @ 4 Amps | |||||||||
Background | 0 - 125 Amps |
|
|
|
|
|
|
| 42 VAC @ 4 Amps | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RECOMMENDED INPUT WIRE AND FUSE SIZES |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
INPUT VOLTAGE |
| FUSE(SUPER LAG) | INPUT AMPERE |
| TYPE 75°C |
| TYPE 75°C | |||||||
AND FREQUENCY |
| OR BREAKER |
| RATING ON |
| COPPER |
| COPPER | ||||||
|
| SIZE |
| NAMEPLATE |
| SUPPLY WIRE |
| GROUND WIRE | ||||||
|
|
|
|
|
|
|
|
|
| IN CONDUIT |
| IN CONDUIT | ||
|
|
|
|
|
|
|
|
|
| AWG (IEC) SIZES |
| AWG (IEC) SIZES | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
200/50/60 |
| 40 |
|
|
| 33 |
|
|
|
|
|
|
| |
220/50/60 |
| 40 |
|
|
| 30 |
|
| 10 (6 mm2) |
| 10 (6 mm2) | |||
380/50/60 |
| 30 |
|
|
| 18 |
|
|
|
|
|
|
| |
415/50/60 |
| 30 |
|
|
| 17 |
|
|
|
|
|
|
| |
440/50/60 |
| 30 |
|
|
| 16 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PHYSICAL DIMENSIONS |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HEIGHT | WIDTH |
|
|
| DEPTH |
|
|
|
| WEIGHT | ||||
23.2 in | 13.2 in. |
|
|
| 24.4 in. |
|
|
|
| 100 lbs. | ||||
589 mm | 336 mm |
|
| 620 mm |
|
| 46 kg | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1At low input voltages (below 208 VAC) and input voltages of 380 VAC through 415 VAC there may be a 15% reduction in Peak Current.
2115 VAC not present on European Models.
INVERTEC STT II (CE)