MAINTENANCE

D-2

 

 

 

PREVENTIVE MAINTENANCE

1.Perform the following preventive maintenance pro- cedures at least once every six months. It is good practice to keep a preventive maintenance record; a record tag attached to the machine works best.

2.Remove the machine wraparound cover and per- form the input filter capacitor discharge procedure (detailed at the beginning of this chapter).

3.Clean the inside of the machine with a low pres- sure airstream. Be sure to clean the following components thoroughly.

Power Switch, Driver, Protection, and Control printed circuit boards

Power Switch

Main Transformer

Input Rectifier

Heat Sink Fins

Input Filter Capacitors

Output Terminals

Lower base compartment

4.Examine capacitors for leakage or oozing. Replace if needed.

5.Examine wraparound cover for dents or breakage. Repair as needed. Cover must be kept in good condition to assure high voltage parts are protected and correct spacings are maintained.

6.Check electrical ground continuity. Using an ohm- meter, measure resistance between either output stud and an unpainted surface of the machine case. Meter reading should be 500,000 ohms or more. If meter reading is less than 500,000 ohms, check for electrical components that are not prop- erly insulated from the case. Correct insulation if needed.

7.Replace machine cover and screws.