CONNECTION OF THE LN-25 WITH K431 REMOTE OPTION TO THE V350-PRO.

NOTE: AN LN-25 CAN ONLY BE USED WITH A FAC- TORY OR “CE” VERSION OF THE V350-PRO.

1.Remove input power to the V350-PRO.

2.Connect the electrode cable to the output terminal of polarity required by the electrode. Connect the work lead to the other terminal. Welding cable must be sized for current and duty cycle of the application.

3.Attach the single lead from the LN-25 control box to the work using the spring clip on the end of the lead. This is only a control lead - it carries no welding current.

4.Set the voltmeter switch to the electrode polarity chosen.

6.Set the “MODE” to the “CV-WIRE” position.

7.Set “WELD TERMINALS SELECT” to the “REMOTE” position.

8.Set the “ARC CONTROL” to the “O” position and then adjust to suit.

9.Connect the K432 remote control cable to the LN- 25.

10.Connect the K876 adapter to the K432 and to the 24/42VAC 14-pin amphenol located at the rear of the V350-PRO.

11.Adjust the wire feed speed and voltage at the LN- 25.

NOTE: See Figure C.4 for connection Using K867 adapter.

5. Set “CONTROL SELECT” to “REMOTE”.

Figure C.3 LN-25 with K431 Remote Option to the V350-PRO

ELECTRODE CABLE

 

 

LN - 25 WITH

TO LN - 25

 

 

14 PIN (24/42VAC)

6 PIN AMPHENOL

K431 OPTION

T O

 

 

 

AMPHENOL

 

 

W O R K

 

 

 

 

 

-

+

INVERTEC POWER SOURCE

K876 ADAPTER

K432 REMOTE

 

CONTROL CABLE

NOTE: Illustration shows electrode connected for positive polarity.