Lochinvar
TST2313, MP2, INS7141, INS7162 installation instructions
Models:
TST2313
INS7162
INS7141
MP2
1
35
36
36
Download
36 pages
38.88 Kb
29
30
31
32
33
34
35
36
<
>
Install
Error codes
Boiler Reset Stand Alone
Fire Delay
External Input Signal Offset
Dip Switch Settings
temperature in the building
Testing The Control
Safety
V ac Power
Page 35
Image 35
NOTES
35
Page 34
Page 36
Page 35
Image 35
Page 34
Page 36
Contents
INSTALLATION INSTRUCTIONS
INTRODUCTION
ADDITIONAL FUNCTIONS INCLUDE
MENU
TABLE OF CONTENTS
ADJUST
USER INTERFACE
Boiler Demand DHW / Setpoint Demand WWSD
SYMBOL DESCRIPTION
DISPLAY
External Input Signal Offset
SECTION A GENERAL OPERATION
Boiler Reset Stand Alone
DEFINITIONS
SEQUENCE OF OPERATION
Fixed Lead Rotation
Alarm
Boiler Alarm
Combustion Air C. A
Mode
Resetting the Rotation Sequence
Resetting the Running Times
SECTION B STAGING OPERATION
Fire Delay
Fire Delay
Lo / Hi
Lo / Lo
Primary Pump Purge
SECTION C PUMP OPERATION
Fixed Differential
Auto Differential
FIG.
SECTION D BOILER RESET OPERATION
Boiler Pump Purge
temperature in the building
This type of a hydronic radiant floor is embedded in either a thick concrete or gypsumpour. This heating system has a large thermal mass and is slow acting FIG
DHW MODE OFF - NO DHW
SECTION E DOMESTIC HOT WATER OPERA- TION
DHW DEMAND
When a DHW Demand is present, the Relay 9 / DHW con- tact terminals 30 and 31 is closed and the primary pump contact is closed. Priority can only be obtained using exter- nal wiring. During a priority override, the Relay 9 / DHW contact is opened until the heating system has recovered before returning to DHW operation, see Figure 19. This mode can be used if a DHW tank is piped in direct return and a DHW valve is installed
SECTION F SET POINT OPERATION
SETP MODE 3 - Primary Pump during Set Point
SECTION G EXTERNAL INPUT OPERATION
SETP MODE 1 - Setpoint in Parallel
SETP MODE 2 - Set Point in Parallel with Priority
2 - 10 V dc or 4 - 20 mA
0 - 10 V dc or 0 - 20 mA
Boiler Demand
INSTALLATION
115 V ac Power
General
Primary Pump Contact Prim P1
Combustion Air / Alarm Contact C.A./Alarm
Set Point Demand
External Input 0 - 10 V dc
Outdoor Sensor
UnOccupied Switch
Relay 9 / DHW
Boiler Return Sensor
Set Point Demand
External Input
Boiler Demand
DHW Demand
Relay 1 to Relay
Combustion Air or Alarm C.A. / Alarm
Primary Pump Prim P1
Relay 9 / DHW
GENERAL
DIP SWITCH SETTINGS
CLEANING THE CONTROL
Page
Page
Page
This item is only available if the External Input / Stand Alone DIP switch is set to Stand Alone
Boil Mass
Stage Delay
Boiler Minimum
Boiler Maximum
m weather
TESTING THE CONTROL
ERROR MESSAGES
is not a safety limit control
TECHNICAL DATA
TYPICAL BOILER INSTALLATION
TYPICAL BOILER INSTALLATION CONTINUED
Tekmar 150 Controller
TYPICAL DWH PRIORITY HEATING PACKAGE SYSTEM