OPERATING PROCEDURE | PHOTOS | |
4. Removing the horizontal vane motor unit | Photo 7 | |
(1) Remove the horizontal vane, the panel (refer to 1.) and the |
| |
corner box. |
| |
(2) Remove the screws of the horizontal vane motor unit, and | Screws of the | |
pull out the horizontal vane motor unit. (Photo 7) | ||
horizontal vane | ||
(3) Disconnect the connector from the horizontal vane motor | ||
motor unit | ||
unit. | ||
|
5. Removing the indoor fan motor and the line flow fan Photo 8 | Motor band | ||
(1) | Remove the horizontal vane, the panel (refer to 1.) and the | ||
| |||
| corner box. |
| |
(2) | Remove the switch holder and the electrical box. (Refer to 3.) |
| |
(3) | Remove the drain hose from the nozzle assembly, and |
| |
| remove the nozzle assembly. |
| |
(4) | Remove the screws fixing the motor bed. (Photo 8) |
| |
(5) Loosen the screw fixing the line flow fan. (Photo 9) |
| ||
(6) | Remove the motor bed together with fan motor and motor |
| |
| band. |
|
(7)Release the hooks of the motor band, and remove the motor band then pull out the indoor fan motor.
(8) | Remove the screws fixing the left side of the heat exchang- | Screws of | |
| er. (Photo 10) | ||
| the motor | ||
(9) | Lift the heat exchanger, and pull out the line flow fan to the | ||
bed | |||
| |||
|
| ||
|
| Photo 9 |
Screw of the line flow fan
Photo 10
Screws of the left side of the heat exchanger
27