OPERATING PROCEDURE | PHOTOS |
2. Removing the electronic control P.C. board, the | Photo 4 |
power monitor receiver P.C. board, SW P.C. board |
|
and the terminal block |
|
(1)Remove the horizontal vane, the panel (refer to 1.) and the corner box.
(2)Remove the screw of the conduit cover, and conduit cover. (Photo 2 or Photo 3)
(3)Remove the indoor/outdoor connecting wire.
(4) | Remove the switch holder from the electrical cover. (Photo |
| Switch holder | |
| 4) |
|
| |
(5) | Remove the screw of the electrical cover, and then the |
|
| |
| electrical cover. (Photo 4) |
| Screw of the | |
(6) | Remove the ground wire connected to the indoor electronic |
| ||
| control P.C. board from the electrical box. (Photo 5) |
| electrical cover. | |
(7) | Unhook the power monitor receiver P.C. board holder from |
|
| |
| the catch. (Photo 4) |
| Power monitor | |
(8) | Open the rear cover of the power monitor receiver P.C. |
| receiver | |
| board holder and pull out the power monitor receiver P.C. |
| P.C. board holder | |
| board. |
|
| |
(9) | Open the switch holder and pull out SW P.C. board. | Photo 5 |
| |
(10) | Pull the electronic control P.C. board slightly toward you | Ground wire | ||
| ||||
| from the electrical box, and disconnect TAB3 and all the |
|
| |
| connectors on the electronic control P.C. board. (LD101 |
| Indoor fan motor | |
| and LD105 are |
| ||
|
| connector (CN211) | ||
| board.) |
| ||
|
| Indoor coil thermistor | ||
(11) Pull out the electronic control P.C. board from the electrical |
| |||
| box. |
| connector (CN112) | |
(12) | Remove the ground wire connected to the heat exchanger |
|
| |
| from the electrical box. (Photo 5) |
|
| |
(13) | Unhook the catches of the electrical box, and pull out the |
| Vane motor | |
| electrical box. |
| ||
|
| connector (CN151) | ||
(14) | Remove the screw of the terminal block cover, and then |
| ||
|
| |||
| remove the terminal block cover and the terminal block |
|
| |
| holder. (Photo 6) |
|
| |
(15) | Remove the terminal block by sliding it. |
|
|
3. Removing the electrical box | Photo 6 |
|
(1)Remove the horizontal vane, the panel (refer to 1.) and the corner box.
(2)Remove the screw of Conduit cover, and then the indoor/ outdoor connecting wire. (Photo 2 or Photo 3)
(3)Remove the switch holder and the electrical cover. (Photo 4)
(4)Remove the ground wire connected to the heat exchang- er from the electrical box. (Photo 5)
(5)Disconnect the following connectors on the electronic control P.C. board; the fan motor connector <CN211>, the indoor coil thermistor connector <CN112>, the vane motor
connector <CN151>. (Photo 5)
(6)Unhook the catches of the electrical box, and pull out the electrical box.