11  MICROPROCESSOR CONTROL

11 MSZ-A09NA MSZ-A17NA MSY-A15NAMSZ-A12NA MSZ-A24NA MSY-A17NA MICROPROCESSOR CONTROL

MSZ-A09NA MSZ-A17NA MSY-A15NA

MSZ-A12NA MSZ-A24NA MSY-A17NA

MSZ-A15NAMSY-A24NA

WIRELESS REMOTE CONTROLLER

WIRELESS REMOTE CONTROLLERThese pictures show MSZ-A24.

Signal transmitting section

Operation display section

ON/OFF (operate/

stop) button

Temperature buttons

Indication of remote controller model is on back

VANE button (Horizontal vane button) INDOOR UNIT DISPLAY SECTION

Operation select button Manual background

ECONO COOL buttonManual backgroundManual backgroundManual background

WIDE VANE button (Vertical vane button) (MSZ-A24, MSY-A24)

POWERFUL button

RESET button Manual background

Fan speed control button

Off-timer button

On-timer button

TIME set buttons

Forward button

Backward button

CLOCK set button

NOTE

Use the remote controller provided with the unit only. Do not use other remote controller.

(This diagram shows anManual backgroundoverall view.)

Once the operation mode is set, the same operation mode can be repeated by simply turning OPERATE/STOP (ON/OFF) button ON.

Indoor unit receives the signal with a beep tone.

When the system turns off, 3-minute time delay will operate to protect system from overload and compressor will not restart for 3 minutes.

INDOOR UNIT DISPLAY SECTION

Operation Indicator lamp

The operation indicator at the right side of the indoor unit indicates the operation state. •The following indication applies regardless of shape of shape of the indication.

 

 

Difference between

Indication

Operation state

target temperature

 

 

and room temperature

 

 

 

 

This shows that the air conditioner is

 

 

operating to reach the target temperature.

Approx. 4°F or more

 

Please wait until the target temperature is

 

 

 

obtained.

 

 

 

 

 

This shows that the room temperature is

Approx. 4°F or less

 

approaching the target temperature.

 

 

 

 

 

 

This shows a state of standby for operation.

 

(For multi system air conditioner)

 

 

 

 

 

Manual background Lighted

Manual background Blinking

Not lighted