3-1. OPERATING RANGE
(1) POWER SUPPLY
| Rated voltage | Guaranteed Voltage (V) | |||||
|
|
|
|
|
|
|
|
| 208/230 V | Min.187 208 | 230 Max.253 | ||||
Indoor unit | 1 phase |
|
|
|
|
|
|
|
|
|
|
|
| ||
| 60 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(2) OPERATION
Mode | Condition |
|
| Intake air temperature (°F) |
|
| |
Indoor |
|
| Outdoor | ||||
|
| DB |
| WB | DB |
| WB |
| Standard temperature | 80 |
| 67 | 95 |
| — |
Cooling | Maximum temperature | 90 |
| 73 | 115 |
| — |
Minimum temperature | 67 |
| 57 | 14 |
| — | |
|
|
| |||||
| Maximum humidity | 78% |
|
| — | ||
Heating | Standard temperature | 70 |
| 60 | 47 |
| 43 |
Maximum temperature | 80 |
| 67 | 75 |
| 65 | |
| Minimum temperature | 70 |
| 60 | 14 |
| 13 |
3-2. OUTLET AIR SPEED AND COVERAGE RANGE
Model | Mode | Function | Air flow (CFM) | Air speed | Coverage | |
(ft./sec.) | range (ft.) | |||||
|
|
|
| |||
HEAT | Dry | 307 | 16.8 | 23.4 | ||
COOL | Dry | 307 | 16.8 | 23.4 | ||
| Wet | 275 | 15.1 | 21.0 | ||
|
| |||||
HEAT | Dry | 353 | 19.3 | 26.7 | ||
COOL | Dry | 353 | 19.3 | 26.7 | ||
| Wet | 318 | 17.4 | 24.1 | ||
|
| |||||
HEAT | Dry | 381 | 20.9 | 28.8 | ||
COOL | Dry | 381 | 20.9 | 28.8 | ||
Wet | 342 | 18.8 | 26.0 | |||
| ||||||
HEAT | Dry | 381 | 20.9 | 28.8 | ||
COOL | Dry | 381 | 20.9 | 28.8 | ||
Wet | 342 | 18.8 | 26.0 | |||
| ||||||
HEAT | Dry | 568 | 20.2 | 34.4 | ||
COOL | Dry | 568 | 20.2 | 34.4 | ||
Wet | 508 | 18.1 | 30.9 | |||
|
●The air coverage range is the figure up to the position where the air speed is 1 ft./sec., when air is blown out horizontally from the unit properly at the High speed position.
The coverage range should be used only as a general guide- line since it varies according to the size of the room and furni- ture arranged inside the room.
5