4. INDOOR UNIT HEAT EXCHANGER

MSZ-A09NA MSZ-A12NA MSZ-A15NA MSZ-A17NA MSY-A15NA MSY-A17NA

4. INDOOR UNIT HEAT EXCHANGER

1

2

3

 

 

 

Symbol

 

 

 

Q'ty/unit

 

 

 

 

No.

Part No.

Part name

in Wiring

 

 

MSZ-

 

MSY-

 

Remarks

 

 

 

Diagram

A09NA

A12NA

A15NA

A17NA

A15NA

A17NA

 

1

E02 A54 620

INDOOR HEAT EXCHANGER

 

1

1

 

 

 

 

 

 

 

E02 A56 620

 

 

 

 

1

1

1

 

1

 

2

E02 815 666

UNION (GAS)

 

1

1

 

 

 

 

 

 

ø3/8

E02 155 666

 

 

 

 

1

1

1

 

1

ø1/2

3

E02 151 667

UNION (LIQUID)

 

1

1

 

1

1

1

 

1

ø1/4

5.AIR CLEANING FILTER (ANTI-ALLERGY ENZYME FILTER)

AIR CLEANING FILTER removes fine dust of 0.01 micron from air by means of static electricity.

Normal life of AIR CLEANING FILTER is 1 year.

If AIR CLEANING FILTER is to be washed, soak AIR CLEANING FILTER in water (when showing dirt, in lukewarm water) and rinse it delicately, without removing the filter from the frame about once every 3 months.

Clogged AIR CLEANING FILTER may reduce the air conditioner capacity or cause frost on the air outlet.

Do not remove or attach AIR CLEANING FILTER during unit operation.

 

Model

Part No.

 

MSZ-A09/12/15/17NA

MAC-415FT-E

 

MSY-A15/17NA

 

 

 

 

 

Replacement of the air cleaning filter

 

(1)Remove the catechin air filter (left one). The air cleaning filter is not attached to the right side catechin air filter.

(2)Remove the air cleaning filter (Blue bel- lows type) from the catechin air filter.

Air cleaning filter (Blue bellows type)

32