| OPERATING PROCEDURE |
| PHOTOS |
|
| |||
4. Removing the vane motor | Photo 4 |
|
| ||||||
(1) | Remove the front panel. (Refer to 1.) |
|
|
|
|
| |||
(2) | Remove the electrical cover. (Refer to 2.) |
|
|
|
|
| |||
| Vane motors | ||||||||
|
| Screws | |||||||
(3) | Remove the lead wire of vane motor. (Refer to 3.) |
|
|
| of the |
| |||
|
|
| |||||||
(4) | Remove the R.L. holder. |
|
|
| vane |
| |||
(5) Pull out the drain hose from the nozzle assembly and remove |
|
|
| motor |
| ||||
| the nozzle assembly. |
|
|
|
|
| |||
|
|
|
|
|
| ||||
(6) | Remove the screws of the vane motor and disconnect the |
|
|
|
|
| |||
| connector. |
|
|
|
|
| |||
(7) | Remove the vane motor. |
|
|
|
|
| |||
|
| Photo 5 |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| Screws of the |
|
|
|
|
| ||
|
| vane motor |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
| Vane motor |
|
|
|
|
|
5. Removing the line flow fan and the indoor fan motor | Photo 6 |
(1)Remove the front panel. (Refer to 1.)
(2)Remove the electrical box. (Refer to 3.)
(3)Remove the drain hose from the nozzle assembly and
| remove the nozzle assembly. |
|
|
(4) | Remove the water cut. |
|
|
| Screws fixing | ||
(5) | Slide the hole cover and remove the hole cover. |
| the left side |
(6) | Remove the hexagon socket set screw from the line flow fan. |
| of the heat |
(7) | Remove the screws fixing the motor bed and remove the fan |
| exchanger |
| motor. (Be careful not to drop the fan motor because it is |
|
|
| heavy.) |
|
|
(8) | Remove the screws fixing the left side of the heat exchang- |
|
|
| er. | Photo 7 |
(9)Lift the left side of the heat exchanger.
(10)Remove the line flow fan.
Water cut
Photo 8
Hole
cover
Screws of the motor bed
29