![](/images/backgrounds/239918/239918-5239x1.png)
Connecting BR24 Radar
SimNet | D | B |
| ||
Network |
|
|
|
| Power |
Scanner cable
C
D
+_
A
F | E |
|
G
H
F
I | I |
J | J |
Key | Description |
AHDS Display.
BBR24 BroadBand™ Radar system for HDS. Includes parts B, C and D (not included in US) and E (2 m 6ft)
CScanner cable. 10 m (33 ft) : Optional 20 m (65 ft) and 30 m (98 ft).
DRI10 Radar interface box (Used with MARPA) (Not included with US version)
EEthernet cable. BR24 comes with a 2 m (6.5 ft) 5 pin cable and a RJ45 cable (US only) The BR24 can be connected directly to HDS or via a Network Expansion Port
(G)
FPower control bus: In this case BR24 is connected to Power Control Bus. BR24 is turned on when the HDS is powered on. Note the yellow wire must be connected to either the power control bus or to 12 V DC supply)
GRC42 Compass
HLSS1 - StructureScan black box
ISimNet drop cable: (0.3 m 1ft, 2 m 6ft or 5 m 15ft ) The RI10 interface box and HDS are connected to the NMEA2000 backbone. BR24 requires heading at 10 hz to calculate MARPA
JSimNet to NMEA2000 adapter kit
38