Installing the Sun SPARCSolaris Fusion-MPT™ Dr ivers 3-5
If the FC disks on your LSI Logic/IntraServer adapter are not identified
by your system, check the following:
1. Are all the FC cables correctly connected to the disk enclosure?
2. Is the disk enclosure powered up?
3. If the external disk enclosure required a loopback connector, is the
loopback connector correctly installed?
3.1.5 Persistent Device Naming
Under certain configurations, such as when the FC disk is the boot
device of a system, it may be preferableto lock a target disk to a unit
number. LSI Logic/IntraServer Fcode allows the system administratorto
write a nonvolatile map of IDs to the FC controller. The followingis an
example of how to map devices in the persistent device table.
Select the controller you want to modify,as shown in Figure 3.3: